 浏览型号DCM420P280M500A40的Datasheet PDF文件第16页浏览型号DCM420P280M500A40的Datasheet PDF文件第17页浏览型号DCM420P280M500A40的Datasheet PDF文件第18页浏览型号DCM420P280M500A40的Datasheet PDF文件第19页浏览型号DCM420P280M500A40的Datasheet PDF文件第21页浏览型号DCM420P280M500A40的Datasheet PDF文件第22页浏览型号DCM420P280M500A40的Datasheet PDF文件第23页浏览型号DCM420P280M500A40的Datasheet PDF文件第24页  
DCM300P280x500A40  
temperature fault is registered, the powertrain immediately stops  
switching, the output voltage of the converter falls, and the converter  
remains disabled for at least time tFAULT. Then, the converter waits for  
the internal temperature to return to below TINT-OTP before  
The ChiP package provides a high degree of flexibility in that it  
presents three pathways to remove heat from internal power  
dissipating components. Heat may be removed from the top surface,  
the bottom surface and the leads. The extent to which these three  
surfaces are cooled is a key component for determining the  
maximum power that is available from a ChiP, as can be seen from  
Figure 20.  
recovering. Provided the converter is still enabled, the DCM will  
restart after tINIT and tON  
.
Output Overvoltage Fault Protection (OVP)  
Since the ChiP has a maximum internal temperature rating, it is  
necessary to estimate this internal temperature based on a real  
thermal solution. Given that there are three pathways to remove heat  
from the ChiP, it is helpful to simplify the thermal solution into a  
roughly equivalent circuit where power dissipation is modeled as a  
current source, isothermal surface temperatures are represented as  
voltage sources and the thermal resistances are represented as  
resistors. Figure 20 shows the "thermal circuit" for a 4623 ChiP DCM,  
in an application where both case top and case bottom, and leads are  
cooled. In this case, the DCM power dissipation is PDTOTAL and the  
The converter monitors the output voltage during each switching  
cycle by a corresponding voltage reflected to the primary side control  
circuitry. If the primary sensed output voltage exceeds VOUT-OVP, the  
OVP fault protection is triggered. The control logic disables the  
powertrain, and the output voltage of the converter falls.  
This type of fault is latched, and the converter will not start again  
until the latch is cleared. Clearing the fault latch is achieved by either  
disabling the converter via the EN pin, or else by removing the input  
power such that the input voltage falls below VIN-INIT  
.
three surface temperatures are represented as TCASE_TOP, TCASE_BOTTOM  
and TLEADS. This thermal system can now be very easily analyzed  
with simple resistors, voltage sources, and a current source.  
,
External Output Capacitance  
The DCM converter internal compensation requires a minimum  
external output capacitor. An external capacitor in the range of 200  
to 2000 µF with ESR of 10 mΩ is required, per DCM for control loop  
compensation purposes.  
This analysis provides an estimate of heat flow through the various  
pathways as well as internal temperature.  
However some DCM models require an increase to the minimum  
external output capacitor value in certain loading and trim  
condition. In applications where the load can go below 10% of rated  
load but the output trim is held constant, the range of output  
capacitor required is given by COUT-EXT-TRANS in the Electrical  
Specifications table. If the load can go below 10% of rated load and  
the DCM output trim is also dynamically varied, the range of output  
capacitor required is given by COUT-EXT-TRANS-TRIM in the Electrical  
Specifications table.  
Thermal Resistance Top  
MAX INTERNAL TEMP  
ΦINT-TOP°C / W  
Thermal Resistance Bottom  
Thermal Resistance Leads  
ΦINT-BOTTOM°C / W  
ΦINT-LEADS°C / W  
+
+
+
T
CASE_BOTTOM(°C)  
TLEADS(°C)  
TCASE_TOP(°C)  
Power Dissipation (W)  
Burst Mode  
Under light load conditions, the DCM converter may operate in burst  
mode depending on the line voltage. Burst mode occurs whenever  
the internal power consumption of the converter combined with the  
external output load is less than the minimum power transfer per  
switching cycle. In order to maintain regulation, the error amplifier  
will switch the powertrain off and on repeatedly, to effectively lower  
the average switching frequency, and permit operation with no  
external load. During the time when the power train is off, the  
module internal consumption is significantly reduced, and so there  
is a notable reduction in no-load input power in burst mode. When  
the load is less than 10% of rated Iout, the output voltage may rise by  
a maximum of 2.95 V, above the output voltage calculated from trim,  
temperature, and load line conditions.  
Figure 20 Double side cooling and leads thermal model  
Alternatively, equations can be written around this circuit and  
analyzed algebraically:  
TINT – PD1 ΦINT-TOP = TCASE_TOP  
TINT – PD2 ΦINT-BOTTOM = TCASE_BOTTOM  
TINT – PD3 ΦINT-LEADS = TLEADS  
PDTOTAL = PD1+ PD2+ PD3  
Where TINT represents the internal temperature and PD1, PD2, and  
PD3 represent the heat flow through the top side, bottom side, and  
leads respectively.  
Thermal Design  
Based on the safe thermal operating area shown in page 5, the full  
rated power of the DCM300P280x500A40 can be processed provided  
that the top, bottom, and leads are all held below 90°C. These curves  
highlight the benefits of dual sided thermal management, but also  
demonstrate the flexibility of the Vicor ChiP platform for customers  
who are limited to cooling only the top or the  
Thermal Resistance Top  
MAX INTERNAL TEMP  
ΦINT-TOP°C / W  
Thermal Resistance Bottom  
Thermal Resistance Leads  
ΦINT-BOTTOM°C / W  
ΦINT-LEADS°C / W  
+
+
T
CASE_BOTTOM(°C)  
TLEADS(°C)  
TCASE_TOP(°C)  
Power Dissipation (W)  
bottom surface.  
The OTP sensor is located on the top side of the internal PCB  
structure. Therefore in order to ensure effective over-temperature  
fault protection, the case bottom temperature must be constrained  
by the thermal solution such that it does not exceed the temperature  
of the case top.  
Figure 21 One side cooling and leads thermal model  
DCMDC-DC Converter  
Rev 1.1  
vicorpower.com  
800 927.9474  
Page 20 of 25  
10/2015  