欢迎访问ic37.com |
会员登录 免费注册
发布采购

BCM4414BG0F4440C06 参数 Datasheet PDF下载

BCM4414BG0F4440C06图片预览
型号: BCM4414BG0F4440C06
PDF下载: 下载PDF文件 查看货源
内容描述: [DC-DC Unregulated Power Supply Module, 1 Output, 1360W, Hybrid, PACKAGE-9]
分类和应用:
文件页数/大小: 43 页 / 3883 K
品牌: VICOR [ VICOR CORPORATION ]
 浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第28页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第29页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第30页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第31页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第33页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第34页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第35页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第36页  
BCM4414xG0F4440yzz  
STATUS_BYTE (78h) and STATUS_WORD (79h)  
STATUS_WORD  
High Byte  
Low Byte  
STATUS_BYTE  
Not Supported: UNKNOWN FAULT OR WARNING  
Not Supported: OTHER  
UNIT IS BUSY  
UNIT IS OFF  
Not Supported: FAN FAULT OR WARNING  
Not Supported: VOUT_OV_FAULT  
POWER_GOOD Negated*  
IOUT_OC_FAULT  
VIN_UV_FAULT  
STATUS_MFR_SPECIFIC  
INPUT FAULT OR WARNING  
TEMPERATURE FAULT OR WARNING  
IOUT/POUT FAULT OR WARNING  
PMBusTM COMMUNCATION EVENT  
NONE OF THE ABOVE  
Not Supported: VOUT FAULT OR WARNING  
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
0
1
1
1
1
0
0
0
1
1
0
1
1
1
1
0
b
* equal to POWER_GOOD#  
All fault or warning flags, if set, will remain asserted until  
cleared by the host or once the BCM and VDDB power is  
removed. This includes undervoltage fault, overvoltage fault,  
overvoltage warning, overcurrent warning, overtemperature  
fault, overtemperature warning, undertemperature fault, reverse  
operation, communication faults and analog controller  
shutdown fault.  
If the BCM controller is powered through VDDB, it will retain the  
last telemetry data and this information will be available to the user  
via a PMBus Status request. This is in agreement with the PMBus  
standard, which requires that status bits remain set until specifically  
cleared. Note that in the case where the BCM VHI is lost, the status  
will always indicate an undervoltage fault, in addition to any other  
fault that occurred.  
Asserted status bits in all status registers, with the exception of  
STATUS_WORD and STATUS_BYTE, can be individually cleared.  
This is done by sending a data byte with one in the bit position  
NONE OF THE ABOVE bit will be asserted if either the  
STATUS_MFR_SPECIFIC (80h) or the High Byte of the  
STATUS WORD is set.  
corresponding to the intended warning or fault to be cleared. Refer  
to the PMBus™ Power System Management Protocol Specification  
– Part II – Revision 1.2 for details.  
STATUS_IOUT (7Bh)  
The POWER_GOOD# bit reflects the state of the device and does  
not reflect the state of the POWER_GOOD# signal limits. The  
POWER_GOOD_ON COMMAND (5Eh) and POWER_GOOD_OFF  
COMMAND (5Fh) are not supported. The POWER_GOOD# bit is  
set, when the BCM is not in the active state, to indicate that the  
powertrain is inactive and not switching. The POWER_GOOD#  
bit is cleared, when the BCM is in the active state, 5ms after the  
powertrain is activated allowing for soft start to elapse.  
POWER_GOOD# and OFF bits cannot be cleared as they always  
reflect the current state of the device.  
IOUT_OC_FAULT  
Not Supported: IOUT_OC_LV_FAULT  
IOUT_OC_WARNING  
Not Supported: IOUT_UC_FAULT  
Not Supported: Current Share Fault  
Not Supported: In Power Limiting Mode  
Not Supported: POUT_OP_FAULT  
Not Supported: POUT_OP_WARNING  
The Busy bit can be cleared using CLEAR_ALL Command (03h) or  
by writing either data value (40h, 80h) to PAGE (00h) using the  
STATUS_BYTE (78h).  
7
6
5
4
3
2
1
0
b
1
0
0
1
0
0
0
0
Fault reporting, such as SMBALERT# signal output, and host  
notification by temporarily acquiring bus master status is  
not supported.  
Unsupported bits are indicated above. A one indicates a fault.  
BCM® in a VIA™ Package  
Page 32 of 43  
Rev 1.2  
01/2018  
 复制成功!