 浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第27页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第28页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第29页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第30页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第32页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第33页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第34页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第35页  
BCM4414xG0F4440yzz  
CLEAR_FAULTS Command (03h)  
OT_FAULT_LIMIT Command (4Fh),  
OT_WARN_ LIMIT Command (51h),  
This command clears all status bits that have been previously set.  
Persistent or active faults are re-asserted again once cleared. All  
faults are latched once asserted in the BCM controller. Registered  
faults will not be cleared when shutting down the BCM  
powertrain by recycling the BCM high side voltage or sending  
the OPERATION command.  
VIN_OV_FAULT_ LIMIT Command (55h),  
VIN_OV_WARN_ LIMIT Command (57h),  
IIN_OC_FAULT_ LIMIT Command (5Bh),  
IIN_OC_WARN_ LIMIT Command (5Dh)  
The values of these registers are set in non-volatile memory and  
can only be written when the BCM is disabled.  
CAPABILITY Command (19h)  
The values of the above mentioned faults and warnings are set by  
default to 100% of the respective BCM model supervisory limits.  
However, these limits can be set to a lower value. For example: In  
order for a limit percentage to be set to 80%, one would send a  
write command with a (50h) Data Word.  
Packet Error Checking is not supported  
Maximum supported bus speed is 400kHz  
The Device does not have SMBALERT# pin and does  
not support the SMBus Alert Response protocol  
Any values outside the range of (00h – 64h) sent by a host will be  
rejected, will not override the currently stored value and will set the  
Unsupported Data bit in STATUS_CML.  
Reserved  
The SET_ALL_THRESHOLDS COMMAND (D5h) combines in one  
block overtemperature fault and warning limits, VHI overvoltage  
fault and warning limits as well as ILO overcurrent fault and warning  
limits. A delay prior to a read command of up to 200ms following a  
write of new value is required.  
7
6
5
4
3
2
1
0
b
0
0
1
0
0
0
0
0
The VIN_UV_WARN_LIMIT (58h) and VIN_UV_FAULT_LIMIT  
(59h) are set by the factory and cannot be changed by the host.  
However, a host can disable the undervoltage setting using the  
DISABLE_FAULT COMMAND (D7h).  
The BCM controller returns a default value of 20h. This value  
indicates that the PMBus™ frequency supported is up to 400kHz  
and that both Packet Error Checking (PEC) and SMBALERT# are  
not supported.  
All FAULT_RESPONSE commands are unsupported. The BCM  
powertrain supervisory limits and powertrain protection will behave  
as described in the Electrical Specifications. In general, once a fault  
is detected, the BCM powertrain will shut down and attempt to  
auto-restart after a predetermined delay.  
TON_DELAY Command (60h)  
The value of this register word is set in non-volatile memory and  
can only be written when the BCM is disabled.  
The maximum possible delay is 100ms. Default value is set  
to (00h). The reported value can be interpreted using the  
following equation.  
TON_DELAYACTUAL = tREPORTED • 10-3(s)  
Staggering start up in an array is possible with the TON_DELAY  
Command. This delay will be in addition to any start up delay  
inherent in the BCM module. For example: start up delay from  
application of VHI is typically 20ms. When TON_DELAY is greater  
than zero, the set delay will be added to it.  
BCM® in a VIA™ Package  
Page 31 of 43  
Rev 1.2  