欢迎访问ic37.com |
会员登录 免费注册
发布采购

BCM4414BG0F4440C06 参数 Datasheet PDF下载

BCM4414BG0F4440C06图片预览
型号: BCM4414BG0F4440C06
PDF下载: 下载PDF文件 查看货源
内容描述: [DC-DC Unregulated Power Supply Module, 1 Output, 1360W, Hybrid, PACKAGE-9]
分类和应用:
文件页数/大小: 43 页 / 3883 K
品牌: VICOR [ VICOR CORPORATION ]
 浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第26页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第27页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第28页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第29页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第31页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第32页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第33页浏览型号BCM4414BG0F4440C06的Datasheet PDF文件第34页  
BCM4414xG0F4440yzz  
Supported Commands Transaction Type  
Page Command (00h)  
A direct communication to the BCM controller and a simulated  
communication to non-PMBus™ devices is enabled by a page  
command. Supported command access privileges with a  
pre-selected PAGE are defined in the following table. Deviation  
from this table generates a communication error in  
STATUS_CML register.  
The page command data byte of 00h prior to a command call will  
address the BCM controller specific data and a page data byte  
of 01h would broadcast to the BCM. The value of the Data Byte  
corresponds to the pin name trailing number with the exception  
of 00h and FFh.  
Data Byte  
Description  
PAGE Data Byte  
Access Type  
00h  
01h  
BCM controller  
BCM  
Command  
Code  
00h  
01h  
PAGE  
00h  
01h  
03h  
19h  
4Fh  
R/W  
R
R/W  
R/W  
W
OPERATION Command (01h)  
OPERATION  
CLEAR_FAULTS  
CAPABILITY  
W
R
The OPERATION command can be used to turn on and off  
the connected BCM.  
OT_FAULT_LIMIT  
OT_WARN_LIMIT  
VIN_OV_FAULT_LIMIT  
VIN_OV_WARN_LIMIT  
IIN_OC_FAULT_LIMIT  
IIN_OC_WARN_LIMIT  
TON_DELAY  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R
If synchronous start up is required in the system, it is recommended  
to use the command from host PMBus in order to achieve  
simultaneous array start up.  
51h  
55h  
57h  
5Bh  
5Dh  
60h  
78h  
79h  
7Bh  
7Ch  
7Dh  
7Eh  
80h  
88h  
89h  
8Bh  
8Ch  
8Dh  
96h  
98h  
99h  
9Ah  
9Bh  
9Ch  
9Dh  
9Eh  
A0h  
A1h  
A4h  
A5h  
A6h  
A7h  
D1h  
D4h  
D5h  
D7h  
Unit is On when asserted (default)  
Reserved  
STATUS_BYTE  
R/W  
R
STATUS_WORD  
STATUS_IOUT  
R
R
R/W  
R/W  
R/W  
STATUS_INPUT  
STATUS_TEMPERATURE  
STATUS_CML  
R
7
6
5
4
3
2
1
0
b
1
0
0
0
0
0
0
0
R
R/W  
R
STATUS_MFR_SPECIFIC  
READ_VIN  
R/W  
R
This command accepts only two data values: 00h and 80h. If any  
other value is sent the command will be rejected and a CML Data  
error will result.  
READ_IIN  
R
R
READ_VOUT  
R
READ_IOUT  
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
READ_TEMPERATURE_1  
READ_POUT  
R
R
PMBUS_REVISION  
MFR_ID  
MFR_MODEL  
R
R
MFR_REVISION  
MFR_LOCATION  
MFR_DATE  
R
R
MFR_SERIAL  
R
MFR_VIN_MIN  
R
MFR_VIN_MAX  
MFR_VOUT_MIN  
MFR_VOUT_MAX  
MFR_IOUT_MAX  
MFR_POUT_MAX  
READ_K_FACTOR  
READ_BCM_ROUT  
SET_ALL_THRESHOLDS  
DISABLE_FAULT  
R
R
R
R
R
R
R
R/W  
R/W  
BCM® in a VIA™ Package  
Page 30 of 43  
Rev 1.2  
01/2018  
 复制成功!