BCM400x500y1K8A3z
BCM Module Through Hole Package Mechanical Drawing and Recommended Land Pattern
6ꢀ.ꢀ4 .ꢀ8
2.494 .01ꢁ
ꢀ1.67
1.247
1.ꢁ2
.060
(2) PL.
8.2ꢁ
.ꢀ2ꢁ
8.00
.ꢀ1ꢁ
11.40
.449
2.7ꢁ
.108
1.ꢀ8
.0ꢁ4
0
0
0
0
1.ꢀ8
.0ꢁ4
2.7ꢁ
.108
4.1ꢀ
.162
22.80 .1ꢀ
.898 .00ꢁ
8.00
.ꢀ1ꢁ
8.2ꢁ
.ꢀ2ꢁ
1.02
.040
(ꢀ) PL.
BOTTOM VIEW
TOP VIEW (COMPONENT SIDE)
11.4ꢀ
.4ꢁ0
.0ꢁ [.002]
7.26 .0ꢁ
.286 .002
SEATING
.
PLANE
.41
.016
(9) PL.
4.17
.164
(9) PL.
1.ꢁ2
.060
(4) PL.
NOTES:
1- RoHS COMPLIANT PER CST-0001 LATEST REVISION.
2- UNLESS SPECIFIED OTHERWISE, DIMESIONS ARE MM / [INCH], TOLERANCE 0.127 / [0.00ꢁ].
1.ꢁ2
.060
PLATED THRU
.2ꢁ [.010]
ANNULAR RING
(ꢀ) PL.
8.2ꢁ .08
.ꢀ2ꢁ .00ꢀ
8.00 .08
.ꢀ1ꢁ .00ꢀ
+VPRI
+VSEC
-VSEC
+VSEC
-VSEC
2.7ꢁ .08
.108 .00ꢀ
1.ꢀ8 .08
.0ꢁ4 .00ꢀ
TM
0
1.ꢀ8 .08
.0ꢁ4 .00ꢀ
0
EN
2.7ꢁ .08
.108 .00ꢀ
4.1ꢀ .08
.162 .00ꢀ
VAUX
8.00 .08
.ꢀ1ꢁ .00ꢀ
8.2ꢁ .08
.ꢀ2ꢁ .00ꢀ
-VPRI
2.0ꢀ
.080
2.0ꢀ
.080
PLATED THRU
.2ꢁ [.010]
ANNULAR RING
(2) PL.
PLATED THRU
.ꢀ8 [.01ꢁ]
ANNULAR RING
(4) PL.
RECOMMENDED HOLE PATTERN
(COMPONENT SIDE)
BCM® Bus Converter
Page 23 of 25
Rev 1.4
07/2015
vicorpower.com