AIM1714xB6MC7D5yzz
Electrical Specifications
Specifications apply over all line and load conditions, 50Hz and 60Hz line frequencies, TC = 25°C, unless otherwise noted.
Boldface specifications apply over the temperature range of the specified product grade.
Attribute
Symbol
Conditions / Notes
Min
85
Typ
Max
Unit
Input Specification
Input Voltage Range,
Continuous Operation
VIN
VIN
264
VRMS
Input Voltage Range,
Transient, Non-Operational (Peak),
30s Minimum Interval
600
V
Source Line Frequency Range
Power Factor
fline
PF
47
63
Hz
-
Please see PFM in VIA package datasheet
for power factor.
Output Specification
Output Power
POUT
IOUT
450
5.3
W
A
Output Current (Continuous)
AIM™ in a VIA Package
Page 6 of 14
Rev 1.2
08/2017