AIM1714xB6MC7D5yzz
Absolute Maximum Ratings
The absolute maximum ratings below are stress ratings only. Operation at or beyond these maximum ratings can cause permanent damage to the device.
Parameter
Comments
Min
Max
Unit
Peak Voltage at Input Terminals,
1ms Max
0
600
Vpk
Input Voltage (AC RMS) Continuous
Output Current (Continuous)
Operating Junction Temperature
Storage Temperature
0
275
5.3
VRMS
ARMS
°C
0
-40
-65
125
125
°C
Input / Output Pin Torque and
Mounting Torque
4 (0.45)
in/lbs (N-m)
AIM™ in a VIA Package
Page 5 of 14
Rev 1.2
08/2017