DANGER! HIGH VOLTAGE!  
DANGER! HOT SURFACE!  
The VI BRICK AC Front End Evaluation Board contains exposed hazardous voltages.  
These voltages are within the area marked by the hashed line on the board.  
The VI BRICK AC Front End Evaluation Board may be operated at surface  
temperatures which may pose a thermal hazard to the operator. Because of the  
thermal and voltage hazards, be careful not to touch any exposed surface unless the  
power is disconnected and the evaluation board has been given sufficient time to cool.  
The evaluation board is not intended for use in end item equipment.  
Set Up  
The Customer Evaluation Board should be set up as follows:  
Note: Care should be taken to avoid reversing polarities if connecting to the opposite  
(solder) side of the board.  
AC Input Connections (J01)  
DANGER! HIGH VOLTAGE!  
J01, the screw terminal connector, is for connection of AC input to the AC-DC  
converter evaluation board. The interconnect leads should be appropriate for the  
current and voltage supplied to the board.  
For single phase power, connect LINE to the pin marked L, NEUTRAL to the pin  
marked N and earth ground to the pin marked EARTH. Corresponding wires in an IEC  
cable are brown, blue, and yellow with a green stripe.  
The board can be used with three phase power. Connect LINE1 to L and LINE2 to N.  
Earth ground should still be connected to the EARTH terminal of J1.  
+OUT, OUT  
There are several connections available on the VI BRICK AC Front End Evaluation  
Board. Table 1 lists the available connectors and their current rating. Do not exceed  
the rating of the connector or the module.  
Tablꢃ 2  
Recommended  
Connector  
Rating  
Connection  
Hold-up capacitor  
Mating PRM and BCM eval  
boards  
Output Connector Ratings  
J02  
J03  
10 A  
12 A (3 A/contact)  
Ring Lugs  
H03 (+OUT) & H07 (-OUT)  
100 A  
12 A  
General Purpose  
Hold-up capacitor  
Output bulk (electrolytic) capacitance must be attached across the output of the VI  
BRICK AC Front End Evaluation Board. Refer to table 1 from previous page for the  
appropriate range of output capacitance.  
vicorpower.com  
Applications Engineering: 800 735.6200  
Rev 1.2  