Fꢀgꢁꢂꢃ 1
VI BRICK AC Front End
Evaluation Board layout and
dimensional drawing,
component side.
(Click on drawing to view larger.)
Basic Specifications and Operating Limits
Please use the following table for operating limits:
Tablꢃ 1
Description
Specification
Notes
Operating Limits
Input Range
85 – 264 Vac
Universal input
Output voltage
48 Vdc
Partially Regulated, SELV
Output Power
330 W Over entire input range
-40 to 100 °C
Operating temperature
Output capacitance
Case temperature
63V rating
6,000 to 12,000μF
Please refer to Figure 1 for locations of the input and output connections as viewed
from the component side. Wires may be soldered directly to the pads instead of ring
lugs if desired to minimize circuit impedances.
vicorpower.com
Applications Engineering: 800 735.6200
Rev 1.2