10-27GHz Detector
CHE1260
Incident power detection versus Incident power @ different frequencies
(Vdetect_I)
10000
10GHz
12GHz
27GHz
17GHz
Vref_I - Vdet_I (mV)
22GHz
1000
100
10
-15 -13 -11 -9 -7 -5 -3 -1
1
3
5
7
9 11 13 15 17 19 21 23 25 27 29
Incident power (dBm)
The CHE1260-98F is a bidirectionnal detector using a symmetrical bidirectionnal coupler.
Therefore the incident power detection versus incident power is identical to the reflective
power detection versus reflected power.
The reflective power detection versus incident power depends on both the coupler directivity
and the reflective environment of the chip.
Incident and reflective power detection versus Incident power @ 10GHz
(Vdetect_I & Vdetect_R)
10000
Vref_I - Vdet_I & Vref_R-Vdet_R (mV)
1000
Incident
Reflective
100
10
-15 -13 -11 -9 -7 -5 -3 -1
1
3
5
7
9 11 13 15 17 19 21 23 25 27 29
Incident power (dBm)
Ref: DSCHE1260-8058 - 28 Feb 08
5/8
Specifications subject to change without notice
Route Départementale 128, B.P.46 - 91401 ORSAY Cedex - FRANCE
Tel.: +33 (0) 1 69 33 03 08 - Fax: +33 (0) 1 69 33 03 09