GA1086
Absolute Maximum Ratings
Storage temperature
Ambient temperature with power applied
Supply voltage to ground potential
DC input voltage
DC input current
Caution:
Damage to the device may occur if an output is shorted to ground or V
DD
.
–65
°C
to +150
°C
–55
°C
to +100
°C
–0.5 V to +7.0 V
–0.5 V to +(V
DD
+ 0.5)
–30 mA to +5 mA
DC Characteristics
(Supply voltage: +5 V + 5% Ambient temp: 0
°
C to +70
°
C)
1
Limits
2
Typ
3.6
0.2
2.0
0.8
–166
0
2
–0.62
–400
25
1000
115
I
IN
= –18 mA
–1.2
0.5
Symbol
V
OH
V
OL
V
IH3
V
IL3
I
IL
I
IH
I
I
I
DD
V
I
4
Description
Output HIGH voltage
Output LOW voltage
Input HIGH level
Input LOW level
Input LOW current
Input HIGH current
Input HIGH current
Power supply current
Input clamp voltage
Test Conditions
V
DD
= Min
I
OH
= –30 mA
V
IN
= V
IH
or V
IL
V
DD
= Min
I
OL
= 30 mA
V
IN
= V
IH
or V
IL
Guaranteed input logical HIGH
voltage for all inputs
Guaranteed input logical LOW
voltage for all inputs
V
DD
= Max
V
DD
= Max
V
DD
= Max
V
DD
= Max
V
DD
= Min
V
IN
= 0.40 V
V
IN
= 2.7 V
V
IN
= 5.5 V
Min
2.4
Max
Unit
V
V
V
µA
µA
µA
160 mA
V
Capacitance
1,5
Symbol
C
IN
Description
Test Conditions
Input capacitance
Min
V
IN
= 2.0 V at f = 1 MHz
Typ
Max
6
Unit
pF
Notes: 1. These values apply to both the GA1086-MC500 and GA1086-MC1000.
2. Typical limits are at V
DD
= 5.0 V and T
A
= 25
°
C.
3. These are absolute values with respect to device ground and all overshoots due to system or tester noise are included.
4. I
DD
is measured with outputs LOW and unloaded.
5. These parameters are not 100% tested, but are periodically sampled.
For additional information and latest specifications, see our website:
www.triquint.com
9
SYSTEM TIMING
PRODUCTS
V