Tripath Technology, Inc. - Technical Information
SYMBOL
VDD
V5
SLEEP
MUTE
TSTORE
TA
PARAMETER
Value
16
6.0
UNITS
V
V
V
V
Supply Voltage
Input Section Supply Voltage
SLEEP Input Voltage
-0.3 to 6.0
-0.3 to V5+0.3
-40 to 150
0 to 70
150
MUTE Input Voltage
Storage Temperature Range
Operating Free-air Temperature Range
Junction Temperature
°C
°C
°C
TJ
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur.
Note 2: See Power Dissipation Derating in the Applications Information section.
O P E R A T I N G C O N D I T I O N S (Note 4)
SYMBOL
VDD
VIH
VIL
PARAMETER
MIN.
8.5
3.5
TYP.
12
MAX. UNITS
Supply Voltage
13.2
V
V
V
High-level Input Voltage (MUTE, SLEEP)
Low-level Input Voltage (MUTE, SLEEP)
1
Note 3: Recommended Operating Conditions indicate conditions for which the device is functional. See
Electrical Characteristics for guaranteed specific performance limits.
T H E R M A L C H A R A C T E R I S T I C S
SYMBOL
PARAMETER
Junction-to-case Thermal Resistance
Junction-to-ambient Thermal Resistance (still air)
VALUE UNITS
2.5
C/W
JC
θ
θ
°
50
C/W
JA
°
2
TA2024B –KL/1.2/01.06