TMC5160 DATASHEET (Rev. 1.08 / 2018-NOV-19)  
83  
12.2.5 Application Example: Joystick Control  
Applications like surveillance cameras can be optimally enhanced using the motion controller: while  
joystick commands operate the motor at a user defined velocity, the target ramp generator ensures  
that the valid motion range never is left.  
REALIZE JOYSTICK CONTROL  
1. Use positioning mode in order to control the motion direction and to set the motion limit(s).  
2. Modify VMAX at any time in the range VSTART to your maximum value. With VSTART=0, you can  
also stop motion by setting VMAX=0. The motion controller will use A1 and AMAX as determined  
by V1 to adapt velocity for ramping up and ramping down.  
3. In case you do not modify the acceleration settings, you do not need to rewrite XTARGET, just  
modify VMAX.  
4. DMAX, D1 and VSTOP only become used when the ramp controller slows down due to reaching  
the target position, or when the target position has been modified to point to the other direction.  
12.3 Velocity Thresholds  
The ramp generator provides a number of velocity thresholds coupled with the actual velocity  
VACTUAL. The different ranges allow programming the motor to the optimum step mode, coil current  
and acceleration settings. Most applications will not require all of the thresholds, but in principle all  
modes can be combined as shown in Figure 12.1. VHIGH and VCOOLTHRS are determined by the  
settings THIGH and TCOOLTHRS in order to allow determination of the velocity when an external step  
source is used. TSTEP becomes compared to these threshold values. A hysteresis of 1/16 TSTEP resp.  
1/32 TSTEP is applied to avoid continuous toggling of the comparison results when a jitter in the  
TSTEP measurement occurs. The upper switching velocity is higher by 1/16, resp. 1/32 of the value set  
as threshold. The stealthChop threshold TPWMTHRS is not shown. It can be included with VPWMTHRS  
< VCOOLTHRS.  
v
VMAX  
VHIGH  
D
X
M
A
M
A
A
X
V1  
D
1
1
A
VCOOLTHRS  
VSTOP  
VSTART  
0
t
current  
I_RUN  
I_HOLD  
VACTUAL  
RMS current  
coolStep current reduction  
Figure 12.3 Ramp generator velocity dependent motor control  
The velocity thresholds for the different chopper modes and sensorless operation features are coupled  
to the time between each two microsteps TSTEP.  