80  
12 Ramp Generator  
The ramp generator allows motion based on target position or target velocity. It automatically  
calculates the optimum motion profile taking into account acceleration and velocity settings. The  
TMC5160 integrates a new type of ramp generator, which offers faster machine operation compared to  
the classical linear acceleration ramps. The sixPoint ramp generator allows adapting the acceleration  
ramps to the torque curves of a stepper motor and uses two different acceleration settings each for  
the acceleration phase and for the deceleration phase. See Figure 12.2.  
12.1 Real World Unit Conversion  
The TMC5160 uses its internal or external clock signal as a time reference for all internal operations.  
Thus, all time, velocity and acceleration settings are referenced to fCLK. For best stability and  
reproducibility, it is recommended to use an external quartz oscillator as a time base, or to provide a  
clock signal from a microcontroller.  
The units of a TMC5160 register content are written as register[5160].  
PARAMETER VS. UNITS  
Parameter / Symbol  
Unit  
calculation / description / comment  
fCLK[Hz]  
s
[Hz]  
[s]  
clock frequency of the TMC5160 in [Hz]  
second  
US  
µstep  
FS  
fullstep  
µsteps / s  
µsteps / s^2  
µstep velocity v[Hz]  
µstep acceleration a[Hz/s]  
v[Hz] = v[5160] * ( fCLK[Hz]/2 / 2^23 )  
a[Hz/s] = a[5160] * fCLK[Hz]^2 / (512*256) / 2^24  
microstep resolution in number of microsteps  
(i.e. the number of microsteps between two  
fullsteps normally 256)  
USC microstep count  
counts  
v[rps] = v[µsteps/s] / USC / FSC  
rotations per second v[rps]  
rps acceleration a[rps/s^2]  
rotations / s  
FSC: motor fullsteps per rotation, e.g. 200  
a[rps/s^2] = a[µsteps/s^2] / USC / FSC  
rs = (v[5160])^2 / a[5160] / 2^8  
rotations / s^2  
ramp steps[µsteps] = rs  
µsteps  
microsteps during linear acceleration ramp  
(assuming acceleration from 0 to v)  
TSTEP = fCLK / fSTEP  
The time reference for velocity thresholds is  
referred to the actual microstep frequency of  
the clock input respectively velocity v[Hz].  
TSTEP, T…THRS  
-
In rare cases, the upper acceleration limit might impose a limitation to the application, e.g. when  
working with a reduced clock frequency or high gearing and low load on the motor. In order to  
increase the effective acceleration possible, the microstep resolution of the sequencer input may be  
decreased. Setting the CHOPCONF options intpol=1 and MRES=%0001 will double the motor velocity for  
the same speed setting and thus also double effective acceleration and deceleration. The motor will  
have the same smoothness, but half position resolution with this setting.  
Quick Start  
For a quick start, see the Quick Configuration Guide in chapter 22.  
www.trinamic.com  
 复制成功!