欢迎访问ic37.com |
会员登录 免费注册
发布采购

TMC5160-TA 参数 Datasheet PDF下载

TMC5160-TA图片预览
型号: TMC5160-TA
PDF下载: 下载PDF文件 查看货源
内容描述: [Universal high voltage controller/driver for two-phase bipolar stepper motor.]
分类和应用: 电动机控制
文件页数/大小: 133 页 / 2799 K
品牌: TRINAMIC [ TRINAMIC MOTION CONTROL GMBH & CO. KG. ]
 浏览型号TMC5160-TA的Datasheet PDF文件第81页浏览型号TMC5160-TA的Datasheet PDF文件第82页浏览型号TMC5160-TA的Datasheet PDF文件第83页浏览型号TMC5160-TA的Datasheet PDF文件第84页浏览型号TMC5160-TA的Datasheet PDF文件第86页浏览型号TMC5160-TA的Datasheet PDF文件第87页浏览型号TMC5160-TA的Datasheet PDF文件第88页浏览型号TMC5160-TA的Datasheet PDF文件第89页  
TMC5160 DATASHEET (Rev. 1.08 / 2018-NOV-19)  
85  
4. As soon as the switch is hit, the position becomes latched and the motor is stopped. Wait until  
the motor is in standstill again by polling the actual velocity VACTUAL or checking vzero or the  
standstill flag.  
5. Switch the ramp generator to hold mode and calculate the difference between the latched  
position and the actual position. For stallGuard based homing or when using hard stop, XACTUAL  
stops exactly at the home position, so there is no difference (0).  
6. Write the calculated difference into the actual position register. Now, homing is finished. A move  
to position 0 will bring back the motor exactly to the switching point. In case stallGuard was  
used for homing, read and write back RAMP_STAT to clear the stallGuard stop event event_stop_sg  
and release the motor from the stop condition.  
HOMING WITH A THIRD SWITCH  
Some applications use an additional home switch, which operates independently of the mechanical  
limit switches. The encoder functionality of the TMC5160 provides an additional source for position  
latching. It allows using the N channel input to snapshot XACTUAL with a rising or falling edge event,  
or both. This function also provides an interrupt output.  
1. Activate the latching function (ENCMODE: Set ignoreAB, clr_cont, neg_edge or pos_edge and  
latch_x_act). The latching function can then trigger the interrupt output (check by reading n_event  
in ENC_STATUS when interrupt is signaled at DIAG0).  
2. Move to the direction, where the N channel switch should be. In case the motor hits a stop  
switch (REFL or REFR) before the home switch is detected, reverse the motion direction.  
3. Read out XLATCH once the switch has been triggered. It gives the position of the switch event.  
4. After detection of the switch event, stop the motor, and subtract XLATCH from the actual position.  
Read and write back ENC_STAT to clear the status flags. (A detailed description of the required  
steps is in the homing procedure above.)  
www.trinamic.com  
 复制成功!