TMC5160 DATASHEET (Rev. 1.08 / 2018-NOV-19)  
53  
6.5.4 PWMCONF Voltage PWM Mode stealthChop  
0X70: PWMCONF VOLTAGE MODE PWM STEALTHCHOP  
Bit Name  
Function  
Comment  
31 PWM_LIM  
PWM automatic scale  
amplitude limit when  
switching on  
Limit for PWM_SCALE_AUTO when switching back from  
spreadCycle to stealthChop. This value defines the upper  
limit for bits 7 to 4 of the automatic current control  
when switching back. It can be set to reduce the current  
jerk during mode change back to stealthChop.  
It does not limit PWM_GRAD or PWM_GRAD_AUTO offset.  
(Default = 12)  
30  
29  
28  
27 PWM_REG Regulation loop  
User defined maximum PWM amplitude change per half  
wave when using pwm_autoscale=1. (1…15):  
1: 0.5 increments (slowest regulation)  
2: 1 increment  
gradient  
26  
25  
24  
3: 1.5 increments  
4: 2 increments (Reset default))  
8: 4 increments  
...  
15: 7.5 increments (fastest regulation)  
23  
22  
21  
20  
-
-
reserved  
reserved  
Allows different  
set to 0  
set to 0  
freewheel1  
freewheel0 standstill modes  
Stand still option when motor current setting is zero  
(I_HOLD=0).  
%00: Normal operation  
%01: Freewheeling  
%10: Coil shorted using LS drivers  
%11: Coil shorted using HS drivers  
19 pwm_  
autograd  
PWM automatic  
gradient adaptation  
0
Fixed value for PWM_GRAD  
(PWM_GRAD_AUTO = PWM_GRAD)  
1
Automatic tuning (only with pwm_autoscale=1)  
(Reset default)  
PWM_GRAD_AUTO is initialized with PWM_GRAD  
while pwm_autograd=0 and becomes optimized  
automatically during motion.  
Preconditions  
1. PWM_OFS_AUTO has been automatically  
initialized. This requires standstill at IRUN for  
>130ms in order to a) detect standstill b) wait >  
128 chopper cycles at IRUN and c) regulate  
PWM_OFS_AUTO so that  
-1 < PWM_SCALE_AUTO < 1  
2. Motor running and 1.5 * PWM_OFS_AUTO <  
PWM_SCALE_SUM < 4* PWM_OFS_AUTO and  
PWM_SCALE_SUM < 255.  
Time required for tuning PWM_GRAD_AUTO  
About 8 fullsteps per change of +/-1.  
Also enables use of reduced chopper frequency for  
tuning PWM_OFS_AUTO.  
18 pwm_  
autoscale  
PWM automatic  
amplitude scaling  
0
1
User defined feed forward PWM amplitude. The  
current settings IRUN and IHOLD have no influence!  
The resulting PWM amplitude (limited to 0…255) is:  
PWM_OFS * ((CS_ACTUAL+1) / 32)  
+ PWM_GRAD * 256 / TSTEP  
Enable automatic current control (Reset default)  
www.trinamic.com  