欢迎访问ic37.com |
会员登录 免费注册
发布采购

TMC5160-TA 参数 Datasheet PDF下载

TMC5160-TA图片预览
型号: TMC5160-TA
PDF下载: 下载PDF文件 查看货源
内容描述: [Universal high voltage controller/driver for two-phase bipolar stepper motor.]
分类和应用: 电动机控制
文件页数/大小: 133 页 / 2799 K
品牌: TRINAMIC [ TRINAMIC MOTION CONTROL GMBH & CO. KG. ]
 浏览型号TMC5160-TA的Datasheet PDF文件第46页浏览型号TMC5160-TA的Datasheet PDF文件第47页浏览型号TMC5160-TA的Datasheet PDF文件第48页浏览型号TMC5160-TA的Datasheet PDF文件第49页浏览型号TMC5160-TA的Datasheet PDF文件第51页浏览型号TMC5160-TA的Datasheet PDF文件第52页浏览型号TMC5160-TA的Datasheet PDF文件第53页浏览型号TMC5160-TA的Datasheet PDF文件第54页  
TMC5160 DATASHEET (Rev. 1.08 / 2018-NOV-19)  
50  
6.5.2 CHOPCONF Chopper Configuration  
0X6C: CHOPCONF CHOPPER CONFIGURATION  
Bit Name  
Function  
Comment  
31 diss2vs  
short to supply  
protection disable  
short to GND  
protection disable  
enable double edge  
step pulses  
0: Short to VS protection is on  
1: Short to VS protection is disabled  
0: Short to GND protection is on  
30 diss2g  
29 dedge  
28 intpol  
1: Short to GND protection is disabled  
1: Enable step impulse at each step edge to reduce step  
frequency requirement.  
1: The actual microstep resolution (MRES) becomes  
extrapolated to 256 microsteps for smoothest motor  
operation (useful for STEP/DIR operation, only)  
%0000:  
Native 256 microstep setting. Normally use this setting  
with the internal motion controller.  
%0001 … %1000:  
interpolation to 256  
microsteps  
27 mres3  
26 mres2  
25 mres1  
24 mres0  
MRES  
micro step resolution  
128, 64, 32, 16, 8, 4, 2, FULLSTEP  
Reduced microstep resolution esp. for STEP/DIR operation.  
The resolution gives the number of microstep entries per  
sine quarter wave.  
The driver automatically uses microstep positions which  
result in a symmetrical wave, when choosing a lower  
microstep resolution.  
step width=2^MRES [microsteps]  
23 tpfd3  
22 tpfd2  
21 tpdf1  
20 tpfd0  
TPFD  
TPFD allows dampening of motor mid-range resonances.  
passive fast decay time Passive fast decay time setting controls duration of the  
fast decay phase inserted after bridge polarity change  
NCLK= 128*TPFD  
%0000: Disable  
%0001 … %1111: 1 … 15  
This bit enables switching to chm=1 and fd=0, when VHIGH  
is exceeded. This way, a higher velocity can be achieved.  
Can be combined with vhighfs=1. If set, the TOFF setting  
automatically becomes doubled during high velocity  
operation in order to avoid doubling of the chopper  
frequency.  
19 vhighchm high velocity chopper  
mode  
18 vhighfs  
high velocity fullstep  
selection  
This bit enables switching to fullstep, when VHIGH is  
exceeded. Switching takes place only at 45° position.  
The fullstep target current uses the current value from  
the microstep table at the 45° position.  
17  
-
reserved  
reserved, set to 0  
16 tbl1  
15 tbl0  
TBL  
%00 … %11:  
blank time select  
Set comparator blank time to 16, 24, 36 or 54 clocks  
Hint: %01 or %10 is recommended for most applications  
14 chm  
chopper mode  
0
1
Standard mode (spreadCycle)  
Constant off time with fast decay time.  
Fast decay time is also terminated when the  
negative nominal current is reached. Fast decay is  
after on time.  
13  
-
reserved  
Reserved, set to 0  
12 disfdcc  
fast decay mode  
chm=1:  
disfdcc=1 disables current comparator usage for termi-  
nation of the fast decay cycle  
chm=1:  
11 fd3  
TFD [3]  
MSB of fast decay time setting TFD  
www.trinamic.com  
 复制成功!