TMC5160 DATASHEET (Rev. 1.08 / 2018-NOV-19)  
55  
6.5.5 DRV_STATUS stallGuard2 Value and Driver Error Flags  
0X6F: DRV_STATUS STALLGUARD2 VALUE AND DRIVER ERROR FLAGS  
Bit Name  
31 stst  
Function  
standstill indicator  
Comment  
This flag indicates motor stand still in each operation mode.  
This occurs 2^20 clocks after the last step pulse.  
1: Open load detected on phase A or B.  
30 olb  
open load indicator  
phase B  
open load indicator  
phase A  
Hint: This is just an informative flag. The driver takes no action  
upon it. False detection may occur in fast motion and  
standstill. Check during slow motion, only.  
29 ola  
1: Short to GND detected on phase A or B. The driver becomes  
disabled. The flags stay active, until the driver is disabled by  
software (TOFF=0) or by the ENN input.  
28 s2gb  
27 s2ga  
26 otpw  
short to ground  
indicator phase B  
short to ground  
indicator phase A  
overtemperature pre-  
warning flag  
1: Overtemperature pre-warning threshold is exceeded.  
The overtemperature pre-warning flag is common for both  
bridges.  
1: Overtemperature limit has been reached. Drivers become  
disabled until otpw is also cleared due to cooling down of the  
25 ot  
overtemperature flag  
IC.  
The overtemperature flag is common for both bridges.  
1: Motor stall detected (SG_RESULT=0) or dcStep stall in dcStep  
mode.  
24 stallGuard stallGuard2 status  
Ignore these bits  
23  
22  
21  
-
reserved  
Actual current control scaling, for monitoring smart energy  
current scaling controlled via settings in register COOLCONF, or  
for monitoring the function of the automatic current scaling.  
20 CS  
actual motor current /  
smart energy current  
ACTUAL  
19  
18  
17  
16  
1: Indicates that the driver has switched to fullstep as defined  
by chopper mode settings and velocity thresholds.  
15 fsactive  
full step active  
indicator  
1: Driver operates in stealthChop mode  
14 stealth  
13 s2vsb  
stealthChop indicator  
short to supply  
indicator phase B  
short to supply  
indicator phase A  
reserved  
1: Short to supply detected on phase A or B. The driver  
becomes disabled. The flags stay active, until the driver is  
disabled by software (TOFF=0) or by the ENN input. Sense  
resistor voltage drop is included in the measurement!  
12 s2vsa  
Ignore this bit  
Ignore this bit  
Mechanical load measurement:  
The stallGuard2 result gives a means to measure mechanical  
motor load. A higher value means lower mechanical load. A  
value of 0 signals highest load. With optimum SGT setting,  
this is an indicator for a motor stall. The stall detection  
compares SG_RESULT to 0 in order to detect a stall. SG_RESULT  
is used as a base for coolStep operation, by comparing it to a  
programmable upper and a lower limit. It is not applicable in  
stealthChop mode.  
11  
10  
9
-
-
reserved  
SG_  
RESULT  
stallGuard2 result  
respectively PWM on  
time for coil A in stand  
still for motor  
8
7
6
5
4
3
2
temperature detection  
1
stallGuard2 works best with microstep operation or dcStep.  
0
Temperature measurement:  
In standstill, no stallGuard2 result can be obtained. SG_RESULT  
shows the chopper on-time for motor coil A instead. Move the  
motor to a determined microstep position at a certain current  
setting to get a rough estimation of motor temperature by a  
reading the chopper on-time. As the motor heats up, its coil  
resistance rises and the chopper on-time increases.  
www.trinamic.com  