TMC5130A DATASHEET (Rev. 1.14 / 2017-MAY-15)  
62  
I
H
D
E
C
target current + hysteresis start  
target current + hysteresis end  
target current  
target current - hysteresis end  
target current - hysteresis start  
on  
sd  
fd  
sd  
t
Figure 8.3 spreadCycle chopper scheme showing coil current during a chopper cycle  
Two parameters control spreadCycle mode:  
Parameter  
HSTRT  
Description  
Setting Comment  
HSTRT=1…8  
Hysteresis start setting. This value is an offset 0…7  
from the hysteresis end value HEND.  
This value adds to HEND.  
HEND  
Hysteresis end setting. Sets the hysteresis end  
value after a number of decrements. The sum  
HSTRT+HEND must be 16. At a current setting of  
max. 30 (amplitude reduced to 240), the sum is  
not limited.  
0…2  
3
-3…-1: negative HEND  
0: zero HEND  
4…15  
1…12: positive HEND  
Even at HSTRT=0 and HEND=0, the TMC5130A sets a minimum hysteresis via analog circuitry.  
EXAMPLE:  
A hysteresis of 4 has been chosen. You might decide to not use hysteresis decrement. In this case  
set:  
HEND=6  
HSTRT=0  
(sets an effective end value of 6-3=3)  
(sets minimum hysteresis, i.e. 1: 3+1=4)  
In order to take advantage of the variable hysteresis, we can set most of the value to the HSTRT, i.e.  
4, and the remaining 1 to hysteresis end. The resulting configuration register values are as follows:  
HEND=0  
HSTRT=6  
(sets an effective end value of -3)  
(sets an effective start value of hysteresis end +7: 7-3=4)  
Hint  
Highest motor velocities sometimes benefit from setting TOFF to 1 or 2 and a short TBL of 1 or 0.  