TMC4671 Datasheet • IC Version V1.00 | Document Revision V1.04 • 2018-Dec-11
25 / 157
Figure 14: Delta Sigma ADC Configurations dsADC_CONFIG (internal: ANALOG vs. external: MCLKO, MCLKI, MDAC)
dsADC_CONGIG Description
NC_MCLKO_MCLKI_MDAC
VIN_MDAT
ANALOG integrated internal ADC mode, MCLK not connected (NC)
VIN (analog)
VIN_MDAT is analog input VIN
MCLKO external dsModulator (e.g. MCLK output
AD7403) with MCLK input
MDAT input
MDAT input
driven by MCLKO
MCLKI external dsModulator (e.g. MCLK input
AD7400) with MCLK output
that drives MCLKI
MDAC external dsModulator (e.g. MDAC output (= MCLK out) MDAT input for CMP
LM339, LM319) realized by
external comparator CMP with
two R and one C
Table 7: Delta Sigma ADC Configurations (figure 14), selected with dsADC_MCFG_A and dsADC_MCFG_B.
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com