TMC4330A Datasheet | Document Revision 1.01 2017-JAN-12  
55/166  
An error flag HOME_ERROR_F is permanently evaluated. This error flag indicates  
whether the current voltage level of the HOME_REF reference input is valid in regard  
to X_HOME and the selected home_event.  
HOME_REF  
Monitoring  
Defining a Home  
Range around  
HOME_REF  
In order to avoid false error flags (HOME_ERROR_F) because of mechanical  
inaccuracies, it is possible to setup an uncertainty home range around X_HOME. In  
this range, the error flag is not evaluated.  
If you want to define an uncertainty area around X_HOME, do as follows:  
Action:  
Set HOME_SAFETY_MARGIN register 0x1E according to the required range [ustep].  
Result:  
The homing uncertainties related to the application environment are considered  
for the ongoing motion. The error flag is NOT evaluated in the following range:  
X_HOME HOME_SAFETY_MARGIN XACTUAL X_HOME + HOME_SAFETY_MARGIN  
NOTE:  
It is recommended to assign to a higher range value for HOME_SAFETY_MARGIN  
in which the HOME_REF level is active for the home_events b’0110, b’0010,  
b’0100, b’1001, b’1011, and b’1101. It avoids false positive HOME_ERROR_Flags.  
After homing with the index channel (home_event = b’0000) for a precise  
assignment of X_HOME the correct home_event has to be assigned in order to  
activate the generation of HOME_ERROR_Flags. Note that home_event = b’0000  
results in HOME_ERROR_Flag=0 permanently.  
The following examples illustrate the points at which the error flag is  
release based on the selected home_event here for home_event = b’0011 (*),  
b’1100 (**), b’0110 (***), b’0010 (***), b’0100 (***), b’1001 (****), b’1011  
(****), and b’1101 (****).  
HOME_SAFETY_MARGIN  
HOME_SAFETY_MARGIN  
X_HOME  
X_HOME  
HOME_REF  
HOME_ERROR_Flag *  
HOME_ERROR_Flag **  
HOME_ERROR_Flag ***  
HOME_ERROR_Flag ****  
HOME_REF  
HOME_ERROR_Flag *  
HOME_ERROR_Flag **  
HOME_ERROR_Flag ***  
HOME_ERROR_Flag ****  
Figure 31: HOME_REF Monitoring and HOME_ERROR_FLAG  
© 2015 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany Terms of delivery and rights  
to technical change reserved. Download newest version at: www.trinamic.com .  
Read entire documentation; especially the Supplemental Directiveson page 160.  