TMC4330A Datasheet | Document Revision 1.01 • 2017-JAN-12
STOPL and STOPR inputs can also be used as HOME_REF inputs.
56/166
Homing with
STOPL or STOPR
OPTION 1: STOPL IS THE HOME SWITCH
Action:
Set stop_left_is_home = 1 (REFERENCE_CONF register 0x01).
Result:
The stop event at STOPL only occurs when the home range is crossed after STOPL
becomes active. The home range is given by X_HOME and HOME_SAFETY_MARGIN.
OPTION 2: STOPR IS HOME SWITCH
Action:
Set stop_right_is_home = 1 (REFERENCE_CONF register 0x01).
Result:
The stop event at STOPR only occurs when the home region is crossed after STOPR
becomes active. The home region is given by X_HOME and HOME_SAFETY_MARGIN.
© 2015 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany — Terms of delivery and rights
to technical change reserved. Download newest version at: www.trinamic.com .
Read entire documentation; especially the “Supplemental Directives” on page 160.
MAIN MANUAL