TMC4330A Datasheet | Document Revision 1.01 2017-JAN-12  
51/166  
When an enabled stop switch becomes active the related status flag is set in the  
STATUS flags register 0x0F. The flag remains active as long as the stop switch remains  
active.  
How Active  
Stops are  
indicated and  
reset to Free  
Motion  
The particular event is also released in the EVENTS register 0x0E, which remains active  
until the event bit is reset manually. When VACTUAL = 0 is reached after the stop  
event no motion toward this particular direction is possible.  
In order to move into the locked direction, the following is required:  
PRECONDITION 1:  
The particular stop switch is NOT active anymore.  
AND/OR  
PRECONDITION 2:  
The stop switch is disabled (stop_left/right_en = 0).  
Action:  
Set back the active event by reading out the EVENTS register 0x0E.  
i
See information about clearing events provided in section 5.1. , page 21.  
Result:  
The active stop event is reset to free motion into the locked direction.  
It is possible to select four different events to store the current internal position  
XACTUAL in the register X_LATCH.  
How to latch  
Internal Position  
on Switch Events  
The table below show which transition of the reference signal leads to the X_LATCH  
transfer. For each transition process the specified reference configurations in the  
REFERENCE_CONF register 0x01 must be set accordingly.  
Reference Configuration  
latch_x_on_inactive_l=1  
latch_x_on_active_l=1  
latch_x_on_inactive_r=1  
latch_x_on_active_r=1  
pol_stop_left=0 pol_stop_left=1 pol_stop_right=0 pol_stop_right=1  
STOPL=0 1  
STOPL=1 0  
---  
---  
STOPL=1 0  
STOPL=0 1  
---  
---  
STOPR=0 1  
STOPR=1 0  
STOPR = 10  
STOPR = 01  
---  
---  
---  
---  
Table 24: Reference Configuration and Corresponding Transition of particular Reference Switch  
Interchange the  
Reference  
If you need to change the directions of the reference switches, do as  
follows:  
Switches  
without Physical  
Reconnection  
Action:  
Set invert_stop_direction=1 (REFERENCE_CONF register 0x01).  
Result:  
STOPL is now the right reference switch and STOPR is now the left reference switch.  
Consequently, all configuration parameters for STOPL become valid for STOPR and  
vice versa.  
© 2015 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany Terms of delivery and rights  
to technical change reserved. Download newest version at: www.trinamic.com .  
Read entire documentation; especially the Supplemental Directiveson page 160.  
MAIN MANUAL   
 