TMC4330A Datasheet | Document Revision 1.01 2017-JAN-12  
48/166  
In some cases, it is useful to switch from external to internal ramp generation during  
motion.  
Switching from  
External to  
Internal Control  
TMC4330A supports a smooth transfer from direct external control to an internal ramp.  
The only parameter you need to know and apply is the current velocity when the  
switching occurs. In more detail, this means that when the external control is switched  
off, VSTART takes over the definition of the actual velocity value. The ramp direction  
is then selected automatically. The time step of the last internal step is also taken into  
account in order to provide a smooth transition from external to internal ramp control.  
In order to select automatic switching from external to internal control, do  
as follows:  
PRECONDITION (EXTERNAL DIRECT CONTROL IS ACTIVE):  
Action:  
Set sdin_mode ≠ b’00 (GENERAL_CONF register 0x00).  
Set sd_indirect_control = 0 (GENERAL_CONF register 0x00).  
Set ASTART = 0 (register 0x2A).  
PROCEED WITH:  
Action:  
Set automatic_direct_sdin_switch_off = 1 (GENERAL_CONF register 0x00) once  
before switching to internal control.  
Continually adapt VSTART register 0x25 according to the actual velocity of the  
TMC4330A that must be calculated in the µC.  
If switching must be prompted, set sdin_mode = b’00.  
Result:  
The internal ramp velocity is started with the value of VSTART, and the direction is  
set automatically on the basis of the external steps that have occurred before.  
Smooth  
Switching for  
S-shaped Ramps  
In order to also support a smooth S-shaped ramp transition - when the external step  
control is switched off - the starting acceleration value can also be set separately at  
ASTART register 0x2A.  
i
In contrast to the automatic direction assignment, the sign of ASTART must be  
set manually.  
In order to select automatic switching from external to internal control with  
a starting acceleration value, do as follows:  
PRECONDITION (EXTERNAL DIRECT CONTROL IS ACTIVE):  
Action:  
Set sdin_mode ≠ b’00 (GENERAL_CONF register 0x00).  
Set sd_indirect_control = 0 (GENERAL_CONF register 0x00).  
PROCEED WITH:  
Action:  
Set automatic_direct_sdin_switch_off = 1 once before switching to internal control.  
Continually adapt VSTART register 0x25 according to the actual velocity of the  
TMC4330A that must be calculated in the µC.  
Continually adapt ASTART according to the actual acceleration (unsigned value) of  
the TMC4330A that must be calculated in the µC.  
Continually set ASTART(31) = 0 or 1 according to the acceleration direction.  
If switching must be prompted, set sdin_mode = b’00.  
Result:  
The internal ramp velocity is started with the value of VSTART, and the direction is  
set automatically on the basis of the external steps that have occurred before. The  
internal acceleration value is set to:  
+ASTART  
ASTART  
if ASTART(31) = 0  
if ASTART(31) = 1.  
or  
© 2015 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany Terms of delivery and rights  
to technical change reserved. Download newest version at: www.trinamic.com .  
Read entire documentation; especially the Supplemental Directiveson page 160.  