7. External Step Control and Electronic Gearing  
Steps can also be generated by external steps that are manipulated internally by an electronic  
gearing process. In the following chapter, steps generation by external control and electronic  
gearing is presented.  
Pins for External Step Control  
Pin Names  
Type  
Remarks  
STPIN  
DIRIN  
Input  
Input  
Step input signal.  
Direction input signal.  
Table 20: Pins used for External Step Control  
Registers used for external Step Control  
Register Name  
Register Address  
Remarks  
GENERAL_CONF  
GEAR_RATIO  
0x00  
0x12  
RW  
RW  
Bits 9:6, 26.  
Electronic gearing factor; signed;  
32 bits=8+24 (8-bit digits, 24-bit decimal places).  
Table 21: Registers used for External Step Control  
Enabling  
External Step  
Control  
In order to synchronize with other motion controllers, TMC4330A offers a step  
direction input interface at the STPIN and DIRIN input pins.  
i
Three options are available. In case one of these options is selected, the internal  
step generator is disabled.  
OPTION 1: HIGH ACTIVE EXTERNAL STEPS  
Action:  
Set sdin_mode = b’01 (GENERAL_CONF register 0x00).  
Result:  
As soon as the STPIN input signal switches to high state the control unit recognizes  
an external step.  
OPTION 2: LOW ACTIVE EXTERNAL STEPS  
Action:  
Set sdin_mode = b’10 (GENERAL_CONF register 0x00).  
Result:  
As soon as the STPIN input signal switches to low state the control unit recognizes an  
external step.  
OPTION 3: TOGGLING EXTERNAL STEPS  
Action:  
Set sdin_mode = b’11 (GENERAL_CONF register 0x00).  
Result:  
As soon as the STPIN input signal switches to low or high state the control unit  
recognizes an external step.  
Continued on next page.  
© 2015 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany Terms of delivery and rights  
to technical change reserved. Download newest version at: www.trinamic.com .  
Read entire documentation; especially the Supplemental Directiveson page 160.  
MAIN MANUAL   
 
 
 复制成功!