2.5” Solid State Disk  
SMART DISABLE OPERATIONS  
Disables the SMART function. Upon receiving the command, the drive disables all SMART operations. This setting is  
maintained when the power is turned off and then back on.  
Once this command has been received, all SMART commands other than SMART ENABLE OPERATIONS are aborted  
with the Aborted Command error.  
This command disables all SMART capabilities including any and all timer and event count functions related exclusively to  
this feature. After command acceptance, this controller will disable all SMART operations. SMART data in no longer be  
monitored or saved. The state of SMART is preserved across power cycles.  
SMART RETURN STATUS  
Reports the drive reliability status.  
Values reported when a predicted defect has not been detected:  
Cylinder Low register: 4Fh  
Cylinder High register: C2h  
Values reported when a predicted defect has been detected:  
Cylinder Low register: F4h  
Cylinder High register: 2Ch  
SMART ENABLE/DISABLE AUTOMATIC OFF-LINE  
Enables (when Sector Count register = “F8h”) or disables (Sector Count register = “00h”) the automatic off-line data  
collection function. The automatic collection is disabled if a value of “00h” is set in the Sector Count register before a  
subcommand is issued. If automatic collection is disabled, the drive can still save attribute information during normal  
operation, such as during the power-on/off sequence or error correction sequence. The automatic collection function is  
enabled if a value of “F8h” is set in the Sector Count register before the command is issued. Values other than “00h” and  
“F8h” are vendor-specific.  