TL284x, TL384x
CURRENT-MODE PWM CONTROLLERS
SLVS038E – JANUARY 1989 – REVISED DECEMBER 1999
†
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage (see Note 1) (I
< 30 mA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Self limiting
CC
Analog input voltage range, V (VFB and ISENSE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 6.3 V
I
Output voltage, V (OUTPUT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 V
O
Input voltage, V , (VC, D package only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 V
I
Supply current, I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 mA
CC
Output current, I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±1 A
O
Error amplifier output sink current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 mA
Package thermal impedance, θ (see Notes 2 and 3): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86°C/W
JA
D-8 package . . . . . . . . . . . . . . . . . . . . . . . . . . 97°C/W
P package . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85°C/W
Virtual junction temperature range, T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 150°C
J
Output energy (capacitive load) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 µJ
Lead temperature, 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
Storage temperature range, T
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
stg
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltages are with respect to the device GND terminal.
2. Maximum power dissipation is a function of T (max), θ , and T . The maximum allowable power dissipation at any allowable
J
JA
A
ambient temperature is P = (T (max) – T )/θ . Operating at the absolute maximum T of 150°C can impact reliability.
D
J
A
JA
J
3. The package thermal impedance is calculated in accordance with JESD 51.
recommended operating conditions
MIN NOM
MAX
30
UNIT
V
‡
Supply voltage, V
and VC
CC
Input voltage, V , RT/CT
0
0
5.5
5.5
30
V
I
Input voltage, V , VFB and ISENSE
V
I
Output voltage, V , OUTPUT
0
V
O
‡
Output voltage, V , POWER GROUND
–0.1
1
V
O
Supply current, externally limited, I
CC
25
mA
mA
mA
kHz
°C
Average output current, I
200
–20
500
125
85
O
Reference output current, I
O(ref)
Oscillator frequency, f
osc
100
Operating virtual junction temperature, T
0
–40
0
J
TL284x
TL384x
Operating free-air temperature, T
A
°C
70
‡
These recommended voltages for V and POWER GROUND apply only to the D package.
C
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265