SN65HVD3080E
SN65HVD3083E
SN65HVD3086E
www.ti.com
SLLS771A–NOVEMBER 2006–REVISED DECEMBER 2006
SUPPLY CURRENT
over recommended operating conditions unless otherwise noted
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX UNIT
Receiver enabled,
Driver enabled
RE at 0 V, D and DE at VCC, No load
375
750
680
µA
µA
µA
nA
Receiver enabled,
Driver disabled
RE at 0 V, D and DE at 0 V, No load
300
240
2
ICC
Supply current
Receiver disabled,
Driver enabled
RE at VCC, D and DE at VCC, No load
RE at VCC, D and DE at 0 V, No load
600
Receiver disabled,
Driver disabled
1000
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range unless otherwise noted
MIN NOM
MAX UNIT
VCC
Supply voltage
4.5
–7(1)
2
5
5.5
V
VI or VIC
VIH
Voltage at any bus terminal (separately or common mode)
12
High-level input voltage
Low-level input voltage
Differential input voltage
D, DE, RE
D, DE, RE
VCC
VIL
0
0.8
12
V
VID
–12
–60
–10
Driver
IOH
High-level output current
Low-level output current
mA
mA
°C
Receiver
Driver
60
10
IOL
Receiver
TJ
Junction temperature
150
85
TA
Ambient still-air temperature
–40
(1) The algebraic convention, in which the least positive (most negative) limit is designated as minimum is used in this data sheet.
3
Submit Documentation Feedback