MSP430F41x2
MIXED SIGNAL MICROCONTROLLER
SLAS648E -- APRIL 2009 -- REVISED MARCH 2011
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted) (continued)
10-bit ADC, power supply and input range conditions (see Note )
PARAMETER
TEST CONDITIONS
V
MIN
2.2
TYP
MAX UNIT
CC
Analog supply voltage
range
V
V
= 0 V
SS
3.6
V
V
CC
Analog input voltage
range (see Note 2)
All Ax terminals,
Analog inputs selected in ADC10AE register
V
Ax
0
V
CC
f
5 MHz,
2.2 V
3 V
0.52
0.6
1.05
1.2
ADC10CLK =
ADC10 supply current
(see Note 3)
ADC10ON = 1, REFON = 0
ADC10SHT0 = 1, ADC10SHT1 = 0, ADC10DIV = 0
I
mA
mA
mA
ADC10
f
5 MHz,
ADC10CLK =
ADC10ON = 0, REF2_5V = 0,
REFON = 1, REFOUT = 0
2.2 V/3 V
3 V
Reference supply
current, reference buffer
disabled (see Note 4)
I
0.25
1.1
0.4
REF+
f
5 MHz,
ADC10CLK =
ADC10ON = 0, REF2_5V = 1,
REFON = 1, REFOUT = 0
f
5 MHz,
ADC10CLK =
Reference buffer supply
current with
ADC10SR = 0
(see Note 4)
2.2 V/3 V
2.2 V/3 V
1.4
1.8
mA
mA
ADC10ON = 0,
REFON = 1, REF2_5V = 0,
REFOUT = 1,
I
I
REFB,0
REFB,1
ADC10SR = 0
f
5 MHz,
ADC10CLK =
2.2 V/3 V
2.2 V/3 V
0.5
0.7
0.8
mA
mA
Reference buffer supply
current with
ADC10SR = 1
(see Note 4)
ADC10ON = 0,
REFON = 1,
REF2_5V = 0,
REFOUT = 1,
ADC10SR = 1
C
R
Input capacitance
Only one terminal Ax selected at a time
27
pF
I
Input MUX ON
resistance
0V V V
2.2 V/3 V
2000
I
Ax
CC
NOTES: 1. The leakage current is defined in the leakage current table with Px.x/Ax parameter.
2. The analog input voltage range must be within the selected reference voltage range V to V for valid conversion results.
R+
R--
3. The internal reference supply current is not included in current consumption parameter I
.
ADC10
4. The internal reference current is supplied via terminal V . Consumption is independent of the ADC10ON control bit, unless a
CC
conversion is active. The REFON bit enables the built-in reference to settle before starting an A/D conversion.
40
POST OFFICE BOX 655303 DALLAS, TEXAS 75265