MSP430F673x
MSP430F672x
SLAS731A –DECEMBER 2011–REVISED APRIL 2012
www.ti.com
Low-Power Mode With LCD Supply Currents (Into VCC) Excluding External Current
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)(1)(2)
Temperature (TA)
PARAMETER
VCC
PMMCOREVx
-40°C
TYP MAX
2.4
25°C
TYP MAX
2.9 3.6
60°C
TYP MAX
3.8
85°C
TYP MAX
5.8
UNIT
Low-power mode 3
(LPM3) current, LCD 4-
mux mode, internal
biasing, charge pump
disabled(3)(4)
0
1
12.2
ILPM3
LCD,
int. bias
2.5
3.1
4.0
6.0
2.2 V
µA
2
2.6
3.3
3.9
3.9
4.2
6.3
13.4
13.3
0
1
2
3
0
1
2
0
1
2
3
2.8
2.9
3.1
3.1
3.2
3.4
3.6
3.6
3.8
3.9
4.0
4.0
4.1
4.2
4.2
4.1
4.3
4.5
4.5
6.4
6.7
7.0
7.0
Low-power mode 3
(LPM3) current, LCD 4-
mux mode, internal
biasing, charge pump
disabled(3)(4)
ILPM3
LCD,
int. bias
3.0 V
2.2 V
3.0 V
µA
µA
µA
4.5
14.7
Low-power mode 3
(LPM3) current, LCD 4-
mux mode, internal
biasing, charge pump
enabled(3)(5)
ILPM3
LCD,CP
(1) All inputs are tied to 0 V or to VCC. Outputs do not source or sink any current.
(2) The currents are characterized with a Micro Crystal MS1V-T1K crystal with a load capacitance of 12.5 pF. The internal and external load
capacitance are chosen to closely match the required 12.5 pF.
(3) Current for watchdog timer clocked by ACLK and RTC clocked by XT1 included. ACLK = low-frequency crystal operation (XTS = 0,
XT1DRIVEx = 0).
CPUOFF = 1, SCG0 = 1, SCG1 = 1, OSCOFF = 0 (LPM3); fACLK = 32768 Hz, fMCLK = fSMCLK = fDCO = 0 MHz
Current for brownout, high-side supervisor (SVSH) normal mode included. Low-side supervisor and monitors disabled (SVSL, SVML).
High-side monitor disabled (SVMH). RAM retention enabled.
(4) LCDMx = 11 (4-mux mode), LCDREXT = 0, LCDEXTBIAS = 0 (internal biasing), LCD2B = 0 (1/3 bias), LCDCPEN = 0 (charge pump
disabled), LCDSSEL = 0, LCDPREx = 101, LCDDIVx = 00011 (fLCD = 32768 Hz / 32 / 4 = 256 Hz)
Even segments S0, S2, ... = 0 and odd segments S1, S3, ... = 1. No LCD panel load.
(5) LCDMx = 11 (4-mux mode), LCDREXT = 0, LCDEXTBIAS = 0 (internal biasing), LCD2B = 0 (1/3 bias), LCDCPEN = 1 (charge pump
enabled), VLCDx = 1000 (VLCD = 3V,typ.), LCDSSEL = 0, LCDPREx = 101, LCDDIVx = 00011 (fLCD = 32768 Hz / 32 / 4 = 256 Hz)
Even segments S0, S2, ... = 0 and odd segments S1, S3, ... = 1. No LCD panel load.
Schmitt-Trigger Inputs – General Purpose I/O
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
1.8 V
3 V
MIN
0.80
1.50
0.45
0.75
0.3
TYP
MAX UNIT
1.40
V
VIT+
VIT–
Vhys
Positive-going input threshold voltage
2.10
1.8 V
3 V
1.00
V
Negative-going input threshold voltage
1.65
1.8 V
3 V
0.85
V
Input voltage hysteresis (VIT+ – VIT–
)
0.4
1.0
For pullup: VIN = VSS
For pulldown: VIN = VCC
RPull
CI
Pullup/pulldown resistor
Input capacitance
20
35
5
50
kΩ
VIN = VSS or VCC
pF
50
Submit Documentation Feedback
Copyright © 2011–2012, Texas Instruments Incorporated