SLOS066E – SEPTEMBER 1975 – REVISED FEBRUARY 1997
LM124, LM124A, LM224, LM224A
LM324, LM324A, LM324Y, LM2902, LM2902Q
QUADRUPLE OPERATIONAL AMPLIFIERS
electrical characteristics at specified free-air temperature, V
CC
= 5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
†
VCC = 5 V to 30 V,
,
VIC = VICRmin, VO = 1.4 V
VO = 1 4 V
1.4
VO = 1 4 V
1.4
TA
‡
25°C
Full range
25°C
IIO
O
IIB
Input offset current
Full range
25°C
Input bias current
Full range
25°C
VICR
Common-mode input
voltage range
VCC = 30 V
Full range
RL = 2 kΩ
VOH
VOL
AVD
CMRR
kSVR
VO1/ VO2
High-level output voltage
VCC = 30 V,
VCC = 30 V,
Low-level output voltage
Large-signal differential
voltage amplification
Common-mode rejection ratio
Supply-voltage rejection ratio
(∆VCC /∆VIO)
Crosstalk attenuation
f = 1 kHz to 20 kHz
VCC = 15 V,
,
VO = 0
IO
Output current
VCC = 15 V,
,
VO = 15 V
VID = – 1 V,
IOS
Short-circuit output current
VCC at 5 V,
VO = 0
VO = 2.5 V,
ICC
Supply current (four amplifiers)
VCC = 30 V,
No load
VID = 1 V,
,
VID = – 1 V,
,
VO = 200 mV
GND at – 5 V,
No load
VO = 15 V,
RL
≤
10 kΩ
VCC = 15 V, VO = 1 V to 11 V,
RL=
≥
2 kΩ
VIC = VICRmin
RL = 2 kΩ
RL
≥
10 kΩ
25°C
Full range
Full range
Full range
Full range
25°C
25°C
25°C
25°C
Full range
25°C
Full range
25°C
25°C
Full range
Full range
– 20
– 10
10
5
12
±
40
0.7
1.4
±
60
1.2
3
25
70
65
120
– 20
– 10
10
5
12
30
±
40
0.7
1.4
±
60
1.2
3
20
0 to
VCC – 1.5
0 to
VCC – 2
VCC – 1.5
26
27
20
25
70
65
80
100
120
– 30
– 60
– 20
– 10
10
5
12
30
±
40
0.7
1.4
±
60
1.2
3
mA
µA
mA
20
mA
LM124A
MIN
TYP
§
MAX
2
4
10
30
– 50
– 100
0 to
VCC – 1.5
0 to
VCC – 2
VCC – 1.5
26
27
28
5
20
15
65
65
80
100
120
– 30
– 60
– 15
MIN
LM224A
TYP
§
2
MAX
3
4
2
30
– 80
– 100
0 to
VCC – 1.5
0 to
VCC – 2
VCC – 1.5
26
27
28
5
20
mV
V/mV
dB
dB
dB
V
– 15
15
2
MIN
LM324A
TYP
§
2
MAX
3
5
30
75
– 100
– 200
nA
nA
mV
UNIT
3–6
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265
Template Release Date: 7–11–94
VIO
O
Input offset voltage
V
† All characteristics are measured under open-loop conditions with zero common-mode input voltage unless otherwise specified.
‡ Full range is –55°C to 125°C for LM124A, – 25°C to 85°C for LM224A, and 0°C to 70°C for LM324A.