LM124, LM124A, LM224, LM224A
LM324, LM324A, LM324Y, LM2902, LM2902Q
QUADRUPLE OPERATIONAL AMPLIFIERS
SLOS066E– SEPTEMBER 1975 – REVISED FEBRUARY1997
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
LM124, LM124A
LM224, LM224A
LM324, LM324A
Supply voltage, VCC (see Note 1)
Differential input voltage, VID (see Note 2)
Input voltage, VI (either input)
Duration of output short circuit (one amplifier) to ground at (or below) TA = 25°C,
VCC
≤
15 V (see Note 3)
Continuous total dissipation
LM124, LM124A
Operating free-air temperature range, TA
free air
range
LM224, LM224A
LM324, LM324A
LM2902, LM2902Q
Storage temperature range
Case temperature for 60 seconds
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds
FK package
J or W package
– 65 to 150
260
300
300
32
±
32
– 0.3 to 32
unlimited
LM2902,
LM2902Q
26
±
26
– 0.3 to 26
unlimited
UNIT
V
V
V
See Dissipation Rating Table
– 55 to 125
– 25 to 85
0 to 70
– 40 to 125
– 65 to 150
°C
°C
°C
°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds D, DB, N, or PW package
260
260
°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values (except differential voltages and VCC specified for the measurement of IOS) are with respect to the network GND.
2. Differential voltages are at IN + with respect to IN –.
3. Short circuits from outputs to VCC can cause excessive heating and eventual destruction.
DISSIPATION RATING TABLE
PACKAGE
D
DB
FK
J (LM124_ )
J (all others)
N
PW
W
TA
≤
25°C
POWER RATING
900 mW
775 mW
900 mW
900 mW
900 mW
900 mW
700 mW
900 mW
DERATING
FACTOR
7.6 mW/°C
6.2 mW/°C
11.0 mW/°C
11.0 mW/°C
8.2 mW/°C
9.2 mW/°C
5.6 mW/°C
8.0 mW/°C
DERATE
ABOVE TA
32°C
25°C
68°C
68°C
40°C
52°C
25°C
37°C
TA = 70°C
POWER RATING
611 mW
496 mW
878 mW
878 mW
654 mW
734 mW
448 mW
636 mW
TA = 85°C
POWER RATING
497 mW
403 mW
713 mW
713 mW
531 mW
596 mW
364 mW
516 mW
TA = 125°C
POWER RATING
N/A
N/A
273 mW
273 mW
N/A
N/A
N/A
196 mW
3–4
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265