ꢀꢁ ꢂꢃ ꢄ ꢅ ꢆ ꢁꢇ ꢈꢂ ꢁꢃ ꢄꢅ ꢆꢁ
ꢉ ꢄ ꢊꢋ ꢌꢍꢀ ꢎ ꢀꢈ ꢏ ꢐꢑ ꢁ ꢀꢒ ꢀ ꢓꢔ
ꢕꢔꢕ ꢂꢓ ꢎ ꢌꢈꢓ ꢌꢍꢀꢎ ꢀ ꢈꢕꢂ ꢁꢓ ꢔꢖ ꢑꢐ ꢈꢑ ꢐ ꢒ
SLAS074D − DECEMBER 1986 − REVISED SEPTEMBER 2003
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range unless otherwise noted
(1)
UNIT
Supply voltage (V
CC+
with respect to V
)
15 V
CC−
Analog input voltage (IN− or IN+)
Reference voltage range
V
V
to V
to V
CC−
CC+
CC−
CC+
Clock input voltage range
0 V to V
CC+
Operating free-air temperature range, T
0°C to 70°C
−65°C to 150°C
260°C
A
Storage temperature range, T
stg
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: N package
(1)
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
MIN
4
NOM
5
MAX
6
UNIT
V
Supply voltage, V
Supply voltage, V
CC+
−3
−5
1
−8
V
CC−
Reference voltage, V
ref
V
High-level input voltage, CLK, RUN/HOLD, V
IH
2.8
V
Low-level input voltage, CLK, RUN/HOLD, V
IL
0.8
V
Differential input voltage, V
ID
V
+1
V
CC+
−0.5
V
CC−
1.2
Maximum operating frequency, f
(see Note 1)
Operating free-air temperature range, T
2
MHz
°C
clock
0
70
A
NOTE 1: Clock frequency range extends down to 0 Hz.
ELECTRICAL CHARACTERISTICS
V
CC+
= 5 V, V
= 5 V, V = 1 V, f = 120 kHz, T = 25°C (unless otherwise noted)
CC−
ref clock A
PARAMETER
TEST CONDITIONS
= −1 mA
MIN
TYP
MAX
UNIT
D1-D5,B1,B2,B4,B8
Other outputs
I
I
I
2.4
4.9
5
5
O
O
O
V
OH
High-level output voltage
Low-level output voltage
V
= −10 µA
V
OL
= 1.6 mA
0.4
V
µV
V
Peak-to-peak output noise voltage (see Note 1)
Zero-reading temperature coefficient of output voltage
High-level input current
V
V
= 0,
= 0,
Full scale = 2 V
0°C ≤ T ≤ 70°C
15
0.5
ON(PP)
VO
ID
ID
α
2
10
µV/°C
µA
A
I
IH
V = 5 V, 0°C ≤ T ≤ 70°C
0.1
I
A
I
Low-level input current
V = 0 V, 0°C ≤ T ≤ 70°C
−0.02
1
−0.1
10
mA
IL
I
A
T
= 25°C
A
I
I
I
Input leakage current, IN− and IN+
Positive supply current
V
= 0
pA
I
ID
0°C ≤ T ≤ 70°C
250
2
A
T
= 25°C
1
−0.8
40
A
f
f
= 0
= 0
mA
CC+
CC−
clock
0°C ≤ T ≤ 70°C
3
A
T
A
= 25°C
−2
−3
Negative supply current
mA
pF
clock
0°C ≤ T ≤ 70°C
A
C
Power dissipation capacitance
See Note 2
pd
NOTES: 1. This is the peak-to-peak value that is not exceeded 95% of the time.
2. Factor-relating clock frequency to increase in supply current. At V
= 5 V, I
= I
(f
= 0) + C × 5 V × f
pd clock
CC+
CC+ CC+ clock
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265