Case 3: Timer enable bit (C8) is 1, Energizing Timing bits (C4:C1) are NOT 0000, and PWM Duty bits
(C7:C5) are NOT 000
The output is turned on in Energizing mode with 100% duty cycle for a duration set by Control register bits
C4:C1. After the timer expires, the output switches to PWM chopping mode with PWM Duty Cycle defined by
Control register bits C7:C5.
Case 4: Timer enable bit (C8) is 1, Energizing Timing bits (C4:C1) are NOT 0000, and PWM Duty bits
(C7:C5) are 000
The output is turned on in Energizing mode with 100% duty cycle for a duration set by Control register bits
C4:C1. After the timer expires, the output is turned off.