AM26C31C, AM26C31I, AM26C31M
QUADRUPLE DIFFERENTIAL LINE DRIVERS
SLLS103G – DECEMBER 1990 – REVISED SEPTEMBER 1998
†
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V
CC
Input voltage range, V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to V
+ 0.5 V
I
CC
Differential input voltage range, V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –14 V to 14 V
ID
Output voltage range, V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V
O
Input or output clamp current, I or I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
IK
OK
Output current, I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±150 mA
O
V
current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 mA
CC
GND current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –200 mA
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Storage temperature range, T
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
stg
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values, except differential output voltage (V ), are with respect to the network ground terminal.
OD
DISSIPATION RATING TABLE
DERATING FACTOR = 70°C
T
≤ 25°C
T
A
T
A
= 85°C
T = 125°C
A
A
PACKAGE
POWER RATING
ABOVE T = 25°C
POWER RATING POWER RATING POWER RATING
A
D
DB
N
950 mW
781 mW
7.6 mW/°C
6.2 mW/°C
9.2 mW/°C
11 mW/°C
11 mW/°C
8.0 mW/°C
608 mW
502 mW
736 mW
—
494 mW
409 mW
598 mW
—
—
—
1150 mW
1375 mW
1375 mW
1000 mW
—
FK
J
275 mW
275 mW
200 mW
—
—
W
—
—
recommended operating conditions
MIN NOM
MAX
UNIT
V
Supply voltage, V
4.5
5
5.5
CC
Differential input voltage, V
±7
V
ID
High-level input voltage, V
2
V
IH
Low-level input voltage, V
0.8
–20
20
V
IL
High-level output current, I
mA
mA
OH
Low-level output current, I
OL
AM26C31C
AM26C31I
AM26C31M
0
–40
–55
70
Operating free-air temperature, T
85
°C
A
125
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265