ADS62P49 / ADS62P29  
ADS62P48 / ADS62P28  
SLAS635AAPRIL 2009REVISED JUNE 2009............................................................................................................................................................. www.ti.com  
Effective Number of Bits (ENOB) – The ENOB is a measure of the converter performance as compared to the  
theoretical limit based on quantization noise.  
SINAD - 1.76  
ENOB =  
6.02  
(3)  
Total Harmonic Distortion (THD) – THD is the ratio of the power of the fundamental (PS) to the power of the  
first nine harmonics (PD).  
PS  
THD = 10Log10  
PN  
(4)  
THD is typically given in units of dBc (dB to carrier).  
Spurious-Free Dynamic Range (SFDR) – The ratio of the power of the fundamental to the highest other  
spectral component (either spur or harmonic). SFDR is typically given in units of dBc (dB to carrier).  
Two-Tone Intermodulation Distortion – IMD3 is the ratio of the power of the fundamental (at frequencies f1  
and f2) to the power of the worst spectral component at either frequency 2f1–f2 or 2f2–f1. IMD3 is either given in  
units of dBc (dB to carrier) when the absolute power of the fundamental is used as the reference, or dBFS (dB to  
full scale) when the power of the fundamental is extrapolated to the converter’s full-scale range.  
DC Power Supply Rejection Ratio (DC PSRR) – The DC PSSR is the ratio of the change in offset error to a  
change in analog supply voltage. The DC PSRR is typically given in units of mV/V.  
AC Power Supply Rejection Ratio (AC PSRR) – AC PSRR is the measure of rejection of variations in the  
supply voltage by the ADC. If ΔVSUP is the change in supply voltage and ΔVout is the resultant change of the  
ADC output code (referred to the input), then  
DVOUT  
PSRR = 20Log10  
(Expressed in dBc)  
DVSUP  
(5)  
Voltage Overload Recovery – The number of clock cycles taken to recover to less than 1% error after an  
overload on the analog inputs. This is tested by separately applying a sine wave signal with 6dB positive and  
negative overload. The deviation of the first few samples after the overload (from their expected values) is noted.  
Common Mode Rejection Ratio (CMRR) – CMRR is the measure of rejection of variation in the analog input  
common-mode by the ADC. If ΔVcm_in is the change in the common-mode voltage of the input pins and ΔVOUT  
is the resultant change of the ADC output code (referred to the input), then  
DVOUT  
10  
CMRR = 20Log  
(Expressed in dBc)  
DVCM  
(6)  
Cross-Talk (only for multi-channel ADC)– This is a measure of the internal coupling of a signal from adjacent  
channel into the channel of interest. It is specified separately for coupling from the immediate neighboring  
channel (near-channel) and for coupling from channel across the package (far-channel). It is usually measured  
by applying a full-scale signal in the adjacent channel. Cross-talk is the ratio of the power of the coupling signal  
(as measured at the output of the channel of interest) to the power of the signal applied at the adjacent channel  
input. It is typically expressed in dBc.  
68  
Submit Documentation Feedback  
Copyright © 2009, Texas Instruments Incorporated  
Product Folder Link(s): ADS62P49 / ADS62P29 ADS62P48 / ADS62P28  