 浏览型号78Q8430-100IGT/F的Datasheet PDF文件第35页浏览型号78Q8430-100IGT/F的Datasheet PDF文件第36页浏览型号78Q8430-100IGT/F的Datasheet PDF文件第37页浏览型号78Q8430-100IGT/F的Datasheet PDF文件第38页浏览型号78Q8430-100IGT/F的Datasheet PDF文件第40页浏览型号78Q8430-100IGT/F的Datasheet PDF文件第41页浏览型号78Q8430-100IGT/F的Datasheet PDF文件第42页浏览型号78Q8430-100IGT/F的Datasheet PDF文件第43页  
DS_8430_001  
78Q8430 Data Sheet  
Hex  
Value Value  
Binary  
Name  
Action Taken  
0x14  
10100b  
THXA  
The high-order nibble of the classification result is assigned the value of  
the high-order nibble value of ‘X’.  
0x15  
0x16  
0x17  
0x18  
10101b  
10110b  
10111b  
11000b  
SETMC Mark the frame as multicast for Rx statistics purposes.  
VLAN Mark the frame as VLAN tagged for length checking and statistics.  
SETBC Mark the frame as broadcast for Rx statistics purposes.  
TOC  
The control logic counter value is initialized to the value contained in the  
Byte Offset field. No offset is applied.  
0x1A  
0x1B  
11010b  
11011b  
DEC  
The control logic counter value is decremented. If the counter has  
reached zero then the control logic will decrement the previous hit value  
used to generate the next CAM reference word by one.  
MCTL  
TDPH  
Classify the frame as a MAC control frame. This also sets the Len/Type  
LSB.  
0x1C  
0x1D  
0x1E  
0x1F  
11100b  
11101b  
11110b  
11111b  
The pause counter most significant byte is set from the frame data.  
TDLTH The Len/Type most significant byte is set from the frame data.  
TDPL  
The pause counter least significant byte is set from the frame data.  
The Len/Type least significant byte is set from the frame data.  
TDLTL  
RCR Match Control  
The value of the Match Control field will determine how the control logic generates the next CAM  
reference word.  
Table 27: RCR Match Control  
Value  
Name  
Action Taken  
00b  
DONE  
No more CAM reference words are generated. No further classification is  
done for the current frame.  
10b  
01b  
MD  
MX  
The next frame data is used to generate the next CAM reference word.  
The ‘X’ value is used in place of the frame data to generate the next CAM  
reference word.  
11b  
DROP  
Drop the frame. If this is executed within the first 128 bytes of the frame  
then the entire frame is dropped from the QUE. No more CAM reference  
words are generated.  
6.7.3 Frame Format  
The following table shows the format of an Ethernet frame. The fields are in the order that the  
classification engine sees them, from left to right. The byte count for each field is specified on the bottom  
row of the table.  
Table 28: Ethernet Frame for Classification  
Destination  
Address  
Source  
Address  
Len/Typ  
Hi Lo  
1B 1B  
LLC Data  
User Pad  
0-1500B 46-0B  
CRC (FCS)  
MSB  
LSB  
6 Bytes  
6 Bytes  
4 Bytes  
If the Len/Type field contains a 16-bit value that is less than 0x0600, the field is interpreted as a length  
field that specifies the number of bytes in the User field. If the value is greater than or equal to 0x0600,  
the type interpretation is to be used.  
6.7.4  
Default CAM Rule Summary  
This section provides the default rules that the 78Q8430B CAM is loaded with on reset.  
Rev. 1.2  
39