must be 12 (allowing for one settling cycle). The required configuration is FIR_LEN = 1 (three cycles per
conversion) and MUX_DIV[1:0] = 01 (4 conversions per mux frame).
During operation, the MPU is in charge of controlling the multiplexer cycles, for example by inserting an
alternate multiplexer sequence at regular intervals using MUX_ALT. This enables temperature
measurement. The polarity of chopping circuitry must be altered for each sample. It must also alternate
for each alternate multiplexer reading. This is accomplished by maintaining CHOP_E = 00.
4.4.5 CE Calculations
The CE performs the precision computations necessary to accurately measure energy. These
computations include offset cancellation, products, product smoothing, product summation, frequency
detection, VAR calculation, sag detection, peak detection, and voltage phase measurement. Refer to the
applicable 78M6612 Firmware Description Document.
4.4.6 CE Status
Since the CE_BUSY interrupt occurs at 2520.6 Hz, it is desirable to minimize the computation required
in the interrupt handler of the MPU. The MPU can read the CE status word at every CE_BUSY interrupt.
CE
Address
Name
CESTATUS
Description
0x70
See description of CE status word below.
The CE Status Word is used for generating early warnings to the MPU. It contains sag warnings for VA
as well as F0, the derived clock operating at the fundamental input frequency. CESTATUS provides
information about the status of voltage and input AC signal frequency, which are useful for generating
early power fail warnings, e.g. to initiate necessary data storage. CESTATUS represents the status flags
for the preceding CE code pass (CE busy interrupt). Sag alarms are not remembered from one code
pass to the next. The CE Status word is refreshed at every CE_BUSY interrupt.
The significance of the bits in CESTATUS is shown in the table below:
CESTATUS
Name
Description
[bit]
31-29
28
Not Used
F0
These unused bits will always be zero.
F0 is a square wave at the exact fundamental input frequency.
27
Reserved
Normally zero. Becomes one when VB remains below SAG_THR for
SAG_CNT samples. Will not return to zero until VB rises above SAG_THR.
26
SAG_B
Normally zero. Becomes one when VA remains below SAG_THR for
SAG_CNT samples. Will not return to zero until VA rises above SAG_THR.
25
SAG_A
24-0
Not Used
These unused bits will always be zero.