 浏览型号71M6533H-IGT/F的Datasheet PDF文件第91页浏览型号71M6533H-IGT/F的Datasheet PDF文件第92页浏览型号71M6533H-IGT/F的Datasheet PDF文件第93页浏览型号71M6533H-IGT/F的Datasheet PDF文件第94页浏览型号71M6533H-IGT/F的Datasheet PDF文件第96页浏览型号71M6533H-IGT/F的Datasheet PDF文件第97页浏览型号71M6533H-IGT/F的Datasheet PDF文件第98页浏览型号71M6533H-IGT/F的Datasheet PDF文件第99页  
FDS_6533_6534_004  
71M6533/71M6534 Data Sheet  
ther 1 or 0. Default is 0 for both (X = 6).  
PULSE_SLOW PULSE_FAST  
PULSE_SLOW  
[0]  
0
X
0
0
1
1
0
1
0
1
1.5 * 22 = 6  
1.5 * 26 = 96  
1.5 * 2-4 = 0.09375  
Do not use  
Table 54: Sag Threshold and Gain Adjust Control  
Default Description  
CE Ad-  
dress  
Name  
The voltage threshold for sag warnings. The default value is  
equivalent to 80 V RMS if VMAX = 600 V.  
2.39*107  
16384  
SAG_THR  
GAIN_ADJ  
0x24  
0x40  
This register scales all voltage and current channels. The  
default value is equivalent to unity gain (1.000).  
4.3.8 CE Transfer Variables  
When the MPU receives the XFER_BUSY interrupt, it knows that fresh data is available in the transfer  
variables. CE transfer variables are modified during the CE code pass that ends with an XFER_BUSY  
interrupt. They remain constant throughout each accumulation interval. In this data sheet, the names of  
CE transfer variables always end with _X. The transfer variables can be categorized as:  
1. Fundamental energy measurement variables  
2. Instantaneous (RMS) values  
3. Other measurement parameters  
Fundamental Energy Measurement Variables  
Table 55 describes each transfer variable for fundamental energy measurement. All variables are signed  
32-bit integers. Accumulated variables such as WSUM are internally scaled so they have at least 2x mar-  
gin before overflow when the integration time is one second. Additionally, the hardware will not permit  
output values to fold back upon overflow.  
Table 55: CE Transfer Variables  
CE Ad-  
Name  
Description  
dress  
0x85  
0x86  
0x87  
0x88  
0x8A  
0x8B  
0x8C  
0x8D  
WSUM_X  
W0SUM_X  
The signed sum: W0SUM_X+W1SUM_X+W2SUM_X.  
The sum of Wh samples from each wattmeter element.  
LSB = 9.4045*10-13 VMAX IMAX / In_8 Wh.  
W1SUM_X  
W2SUM_X  
VARSUM_X  
VAR0SUM_X  
VAR1SUM_X  
VAR2SUM_X  
The signed sum: VAR0SUM_X+VAR1SUM_X+VAR2SUM_X.  
The sum of VARh samples from each wattmeter element.  
LSB = 9.4045*10-13 VMAX IMAX / In_8 VARh.  
WxSUM_X and VARSUM_X are the signed sum of Phase-A, Phase-B and Phase-C Wh or VARh values  
according to the metering equation specified in the I/O RAM register EQU. WxSUM_X is the Wh value  
accumulated for phase x in the last accumulation interval and can be computed based on the specified  
LSB value.  
For example, with VMAX = 600 V and IMAX = 208 A, the LSB for WxSUM_X is 0.1173 µWh.  
v1.1  