 浏览型号71M6515H-IGTR/F的Datasheet PDF文件第32页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第33页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第34页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第35页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第37页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第38页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第39页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第40页  
71M6515H  
Energy Meter IC  
DATA SHEET  
MARCH 2008  
Bits 13-8: These six bits (SUM_CYCLES) define the length of the accumulation interval τ per the formula:  
SUM _ CYCLES 42  
τ =  
2520.6  
Allowed values are 24 (400ms) through 60 (1000ms), unless the post-processor is disabled. Bit 8 is the LSB.  
It is important to note that the length of the accumulation interval, as determined by SUM_CYCLES, is not an exact multiple  
of 1000ms. For example, if SUM_CYCLES = 60, the resulting accumulation interval is:  
6042  
32768Hz  
13  
2520  
τ =  
=
= 999.75ms  
2520.62Hz  
This means that accurate time measurements should be based on the RTC, not the accumulation interval.  
Bit 14: This bit (CKOUT_DISB) disables the CKOUT pin when set. The CKOUT pin can be used for diagnostics. For EMC  
compliance and power saving reasons, CKOUT_DISB should always be set.  
Bit 15: This bit (ADC_DIS) disables the ADC when set, e.g. to save power. Of course, no metering or measuring can be  
performed with the ADC disabled.  
Bits 18-16: These three bits (TMUX) select the source for the TMUX diagnostic output pin. For EMC compliance and  
power saving reasons, TMUX should be zero (default) if unused.  
Bit 18  
TMUX2  
Bit 17  
TMUX1  
Bit 16  
TMUX0  
TMUX  
Signal Selected for the TMUX Pin  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
0
1
2
3
4
5
6
7
GND  
MUX_SYNC  
RTM  
RTC Output  
CE_BUSY  
XFER_BUSY  
VX_OK (Comparator Output)  
V3P3/2 =1.5V internal analog voltage  
Bits 20-19: These two bits (F_SELECT) select the phase that is to be used for frequency measurement. The frequency will  
be shown in bits 31-16 of the FREQ_DELTA_T register (and as bit 4 of the STATUS word – in this form as a digitized zero  
crossing signal).  
Bit 20  
Bit 19  
Phase  
F_SELECT  
F_SELECT1 F_SELECT0  
Selected  
Phase A  
Phase B  
Phase C  
Not allowed  
0
0
1
1
0
1
0
1
0
1
2
3
Since the signal at the input selected with F_SELECT is used to synchronize filters and other processing stages in the CE,  
accuracy for most measurements will be reduced if no voltage is present at the selected phase input. Accuracy can be  
established by selecting the phase that carries a stable signal (A, B, or C).  
Bit 21: This bit (CE_ONLY) disables the post-processor when set to 1. When the post-processor is disabled, the time-  
intensive computations of IPHASE, IRMS, VAh and VRMS are not performed, and therefore smaller accumulation times  
(SUM_CYCLES < 24) are permitted. In this case, the host is responsible for calculating IPHASE, IRMS, VAh and VRMS.  
Page: 36 of 57  
© 2005-2008 TERIDIAN Semiconductor Corporation  
V1.4  