71M6513/71M6513H
3-Phase Energy Meter IC
A Maxim Integrated Products Brand
DATA SHEET
SEPTEMBER 2011
Serial Interface 1 Control Register (S1CON).
The function of the serial port depends on the setting of the Serial Port Control Register S1CON.
MSB
LSB
RI1
SM
-
SM21
REN1
TB81
RB81
TI1
Table 15: The S1CON register
Bit
Symbol
Function
S0CON.7
SM0
These two bits set the UART0 mode:
Mode
Description
SM0
SM1
0
N/A
0
0
1
0
1
1
2
3
8-bit UART
9-bit UART
9-bit UART
0
1
1
S0CON.6
SM1
S0CON.5
S0CON.4
S0CON.3
SM20
REN0
TB80
Enables the inter-processor communication feature.
If set, enables serial reception. Cleared by software to disable reception.
The 9th transmitted data bit in Modes 2 and 3. Set or cleared by the
MPU, depending on the function it performs (parity check, multiprocessor
communication etc.)
S0CON.2
RB80
In Modes 2 and 3 it is the 9th data bit received. In Mode 1, if SM20 is 0,
RB80 is the stop bit. In Mode 0 this bit is not used. Must be cleared by
software
S0CON.1
S0CON.0
TI0
RI0
Transmit interrupt flag, set by hardware after completion of a serial
transfer. Must be cleared by software.
Receive interrupt flag, set by hardware after completion of a serial
reception. Must be cleared by software
Table 16: The S0CON Bit Functions
© 2005-2011 Teridian Semiconductor Corporation
Page: 25 of 104