71M6513/71M6513H  
3-Phase Energy Meter IC  
A Maxim Integrated Products Brand  
DATA SHEET  
AUGUST 2011  
WDCON[7] selects whether timer 1 or the internal baud rate generator is used. All UART transfers are programmable for parity  
enable, parity, 2 stop bits/1 stop bit and XON/XOFF options for variable communication baud rates from 300 to 38400 bps.  
Table 12 shows how the baud rates are calculated. Table 13 shows the selectable UART operation modes.  
Using Timer 1  
Using Internal Baud Rate Generator  
2smod * fCKMPU/ (384 * (256-TH1))  
2smod * fCKMPU/(64 * (210-S0REL))  
fCKMPU/(32 * (210-S1REL))  
Serial Interface 0  
Serial Interface 1  
N/A  
Note: S0REL and S1REL are 10-bit values derived by combining bits from the respective timer reload registers. SMOD is the  
SMOD bit in the SFR PCON. TH1 is the high byte of timer 1.  
Table 12: Baud Rate Generation  
UART 0  
UART 1  
Start bit, 8 data bits, parity, stop bit, variable  
baud rate (internal baud rate generator)  
Mode 0  
Mode 1  
N/A  
Start bit, 8 data bits, stop bit,  
variable baud rate (internal baud  
rate generator or timer 1)  
Start bit, 8 data bits, stop bit, variable baud rate  
(internal baud rate generator)  
Start bit, 8 data bits, parity, stop bit,  
fixed baud rate 1/32 or 1/64 of  
fCKMPU  
Mode 2  
Mode 3  
N/A  
N/A  
Start bit, 8 data bits, parity, stop bit,  
variable baud rate (internal baud  
rate generator or timer 1)  
Table 13: UART Modes  
Note: Parity of serial data is available through the P flag of the accumulator. Seven-bit serial modes with parity, such as those  
used by the FLAG protocol, can be simulated by setting and reading bit 7 of 8-bit output data. Seven-bit serial modes without  
parity can be simulated by setting bit 7 to a constant 1. 8-bit serial modes with parity can be simulated by setting and reading  
the 9th bit, using the control bits TB80 (S0CON.3) and TB81 (S1CON.3) in the S0CON and S1CON SFRs for transmit and RB81  
(S1CON.2) for receive operations. SM20 (S0CON.5) and SM21 (S1CON.5) can be used as handshake signals for inter-processor  
communication in multi-processor systems.  
Serial Interface 0 Control Register (S0CON).  
The function of the UART0 depends on the setting of the Serial Port Control Register S0CON.  
MSB  
SM0  
LSB  
RI0  
SM1  
SM20  
REN0  
TB80  
RB80  
TI0  
Table 14: The S0CON Register  
Page: 24 of 104  
© 2005-2011 Teridian Semiconductor Corporation