Battrax Dual Positive/Negative SLIC Protector
Battrax Dual Positive/Negative SLIC Protector
(+VREF
)
This Battrax device protects Subscriber Line Interface Circuits (SLIC) that use both a
5
positive and negative Ring voltage. It limits transient voltages with rise times of 100 V/
µs to V
±10 V.
REF
Ground
4, 6
Teccor’s six-pin Battrax devices are constructed using four SCRs and four gate diodes.
The SCRs conduct when a voltage that is more negative than -V (and/or more
REF
positive than +V
) is applied to the cathode (Pins 1 and 3) of the SCR. During
REF
conduction, the SCRs appear as a low-resistive path which forces all transients to be
shorted to ground.
2
3
(R)
1
(T)
(-VREF
)
For a diagram of a Battrax application, see Figure 3.30.
Electrical Parameters
Part
VDRM
Volts
VS
VT
IDRM
IGT
IT
IH
CO
pF
Number *
Volts
Volts
µAmps
mAmps
Amps
mAmps
B3104U_
B3164U_
B3204U_
|-VREF| + |±1.2V|
|-VREF| + |±1.2V|
|-VREF| + |±1.2V|
|-VREF| + |±10V|
|-VREF| + |±10V|
|-VREF| + |±10V|
4
4
4
5
5
5
100
100
100
1
1
1
100
160
200
50
50
50
* For individual “UA” and “UC” surge ratings, see table below.
General Notes:
•
•
•
•
•
•
•
•
•
All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
I
PP is a repetitive surge rating and is guaranteed for the life of the product.
PP ratings assume a VREF = ±48 V.
I
V
DRM is measured at IDRM.
VS is measured at 100 V/µs.
Off-state capacitance is measured at 1 MHz with a 2 V bias and is a typical value. “UC” product is approximately 2x the listed value.
Positive Battrax information is preliminary data.
V
V
REF maximum value for the negative Battrax is -200 V.
REF maximum value for the positive Battrax is 110 V.
Surge Ratings
IPP
IPP
IPP
IPP
IPP
ITSM
60 Hz
Amps
2x10 µs
Amps
8x20 µs
Amps
10x160 µs
Amps
10x560 µs
Amps
10x1000 µs
Amps
di/dt
Series
A
C**
Amps/µs
150
500
150
400
90
200
50
120
45
100
20
50
500
500
** Call factory for release date.