General
Specifications
C Series – General Application
No.
1
Item
Performance
Test or Inspection Method
External
Appearance
No defects which may affect
performance.
Inspect with magnifying glass (3×), in case of C0603
type, with magnifying glass (10×).
2
Insulation
10,000MΩ or 500MΩ•μF min.
Apply rated voltage for 60s. As for the rated voltage
Resistance
630V DC, apply 500V DC.
(As for the capacitors of rated voltage
16, 10 and 6.3V DC, 10,000 MΩ or
100MΩ•μF min.,) whichever smaller.
3
Voltage Proof
Capacitance
Withstand test voltage without
insulation breakdown or other damage.
Class
Apply voltage
Class 1 3 × rated voltage
Class 2 2.5 × rated voltage
Above DC voltage shall be applied for 1 to 5s. Charge /
discharge current shall not exceed 50mA.
4
Within the specified tolerance.
Measuring
Frequency
1MHz±10%
1kHz±10%
Rated
Capacitance
Measuring
voltage
Class
C ≤ 1000pF
Class 1
0.5 - 5 Vrms
C >1000pF
0.5±0.2Vrms
1.0±0.2Vrms
0.5±0.2 Vrms
C ≤ 10uF
1kHz±10%
Class 2
C > 10uF
120Hz±20%
5
6
Q
See No.4 in this table for measuring condition.
Rated Capacitance
30pF and over
Under 30pF
Q
(Class 1)
1,000 min.
400+20×C min.
C : Rated capacitance (pF)
Dissipation
Factor
See No.4 in this table for measuring condition.
T.C.
Rated
D.F.
Voltage
(Class 2)
X5R
X7R
-
0.03 max.
0.05 max.
0.75 max.
0.1 max.
0.125 max.
0.15 max.
0.05 max.
0.075 max.
0.10 max.
0.125 max.
0.20 max.
Y5V
50VDC
25VDC
16VDC
10VDC
6.3VDC
TDK MLCC US Catalog
Page 64
Version B11