 浏览型号TCS3414的Datasheet PDF文件第18页浏览型号TCS3414的Datasheet PDF文件第19页浏览型号TCS3414的Datasheet PDF文件第20页浏览型号TCS3414的Datasheet PDF文件第21页浏览型号TCS3414的Datasheet PDF文件第23页浏览型号TCS3414的Datasheet PDF文件第24页浏览型号TCS3414的Datasheet PDF文件第25页浏览型号TCS3414的Datasheet PDF文件第26页  
TCS3404, TCS3414  
DIGITAL COLOR SENSORS  
TAOS137A − APRIL 2011  
// Read ADC Channels Using Read Byte Protocol  
Address = 0x39  
//Slave addr − also 0x29 or 0x49  
//Address the Ch1 lower data register  
//Result returned in DataLow  
//Address the Ch1 upper data register  
//Result returned in DataHigh  
//Shift DataHigh to upper byte  
//Address the Ch2 lower data register  
//Result returned in DataLow  
//Address the Ch2 upper data register  
//Result returned in DataHigh  
//Shift DataHigh to upper byte  
//Address the Ch3 lower data register  
//Result returned in DataLow  
//Address the Ch3 upper data register  
//Result returned in DataHigh  
//Shift DataHigh to upper byte  
//Address the Ch4 lower data register  
//Result returned in DataLow  
//Address the Ch4 upper data register  
//Result returned in DataHigh  
Command = 0x90  
ReadByte (Address, Command, DataLow)  
Command = 0x91  
ReadByte (Address, Command, DataHigh)  
Channel1 = 256 * DataHigh + DataLow  
Command = 0x92  
ReadByte (Address, Command, DataLow)  
Command = 0x93  
ReadByte (Address, Command, DataHigh)  
Channel2 = 256 * DataHigh + DataLow  
Command = 0x94  
ReadByte (Address, Command, DataLow)  
Command = 0x95  
ReadByte (Address, Command, DataHigh)  
Channel3 = 256 * DataHigh + DataLow  
Command = 0x96  
ReadByte (Address, Command, DataLow)  
Command = 0x97  
ReadByte (Address, Command, DataHigh)  
Channel4 = 256 * DataHigh + DataLow  
//Shift DataHigh to upper byte  
Copyright E 2011, TAOS Inc.  