C2510Fx / CC2511Fx
Parameter
Min
Typ
Max
Unit Condition/Note
Single ended input
(-THD+N)
46.8
57.5
66.6
40.7
51.6
61.8
70.8
20
dB
dB
dB
dB
dB
dB
dB
9-bits setting
10-bits setting
12-bits setting
7-bits setting
9-bits setting
10-bits setting
12-bits setting
7-bits setting
9-bits setting
10-bits setting
12-bits setting
SINAD4
Differential input
(-THD+N)
Conversion time
µs
µs
36
68
µs
132
µs
Current consumption
1.2
mA
Table 18: 7-12 bit ADC Characteristics
7.11 Control AC Characteristics
TA = 25 °C, VDD = 3.0 V if nothing else stated. All measurement results are obtained using the
CC2510EM reference designs ([1]).
Parameter
Min
Typ
Max
Unit
Condition/Note
System clock,
fSYSCLK
CC2510Fx
tSYSCLK= 1/ fSYSCLK
0.1875
0.1875
26
13
27
MHz
MHz
High speed crystal oscillator used as source (HS XOSC)
Calibrated HS RCOSC used as source.
13.5
HS
HS
XOSC
RCOSC
111
000
000
111
001
001
Min: fXOSC = 24 MHz, CLKCON.CLKSPD=
Typ: fXOSC = 26 MHz, CLKCON.CLKSPD=
Max: fXOSC = 27 MHz, CLKCON.CLKSPD=
CC2511Fx
0.1875
0.1875
24
12
24
12
MHz
ns
High speed crystal oscillator used as source.
HS RCOSC used as source.
Min: fXOSC = 48 MHz, CLKCON.CLKSPD= 111
Typ and Max: fXOSC = 48 MHz, CLKCON.CLKSPD= 000
RESET_N low
width
250
See item 1, Figure 4. This is the shortest pulse that is
guaranteed to be recognized as a reset pin request.
Note: Shorter pulses may be recognized but will not lead to
complete reset of all modules within the chip.
Interrupt pulse
width
tSYSCLK
See item 2, Figure 4. This is the shortest pulse that is
guaranteed to be recognized as an interrupt request. In PM2/3
the internal synchronizers are bypassed so this requirement
does not apply in PM2/3.
Table 19: Control Inputs AC Characteristics
SWRS055D
Page 21 of 243