RELIABILITY DATA  
16. Humidity Loading  
Appearance:  
No abnormality  
Capacitance change: Within ±7.5% or ±0.75pF, whichever is larger.  
Standard  
Q:  
C30pFQ10010C/3  
C30pFQ200  
CNominal capacitance)  
Temperature Compensating  
Class 1)  
Insulation resistance: 500 MΩ min.  
Appearance: No abnormality  
Capacitance change: C2pFWithin ±0.4 pF  
Specified  
Value  
High Frequency Type  
C2pFWithin ±0.75 pF  
CNominal capacitance)  
Insulation resistance: 500 MΩ min.  
Appearance:  
No abnormality  
Capacitance change: Within ±12.5%BJ, B7, C6, C7)  
Within ±30%F)  
High PermittivityClass 2Note 1  
Dissipation factor:  
5.0% max.BJ, B7, C6, C7)  
11.0% max. F)  
Insulation resistance: 25 MΩμF or 500 MΩ, whichever is smaller.  
Test Methods and Remarks】  
Class 1  
Class 2  
Standard  
High Frequency Type  
All items  
Preconditioning  
Temperature  
Humidity  
None  
Preconditioning  
Voltage treatment  
Rated voltage are applied for 1 hour at 40Note 3  
40±2℃  
60±2℃  
Temperature  
Humidity  
40±2℃  
90 to 95RH  
50024/0 hrs  
90 to 95RH  
Duration  
50024/0 hrs  
Rated voltage  
50mA max.  
Duration  
Applied voltage  
Charge/discharge current  
Recovery  
Applied voltage  
Charge/discharge current  
Recovery  
Rated voltage  
50mA max.  
6 to 24 hrsStandard conditionNote 5  
24±2 hrsStandard conditionNote 5  
17. High Temperature Loading  
Appearance:  
No abnormality  
Capacitance change: Within ±3% or ±0.3pF, whichever is larger.  
QC10pFQ20010C  
10C30pFQ2752.5C  
C30pFQ350CNominal capacitance)  
Insulation resistance: 1000 MΩ min.  
Appearance: No abnormality  
Standard  
Temperature Compensating  
Class 1)  
Specified  
Value  
High Frequency Type Capacitance change: Within ±3% or ±0.3pF, whichever is larger.  
Insulation resistance: 1000 MΩ min.  
Appearance:  
No abnormality  
Capacitance change: Within ±12.5%BJ, B7, C6, C7)  
Within ±30%F)  
High PermittivityClass 2Note 1  
Dissipation factor:  
5.0% max. BJ, B7, C6, C7)  
11.0% max. F)  
Insulation resistance: 50 MΩμF or 1000 MΩ, whichever is smaller.  
Test Methods and Remarks】  
Class 1  
Class 2  
Standard  
High Frequency Type  
BJ, F  
C6  
B7, C7  
Preconditioning  
Temperature  
None  
Preconditioning  
Voltage treatmentTwice the rated voltage shall be  
applied for 1 hour at 85, 105or 125Note 3, 4  
125±3℃  
Temperature  
Duration  
85±2℃  
105±3℃  
100048/0 hrs  
Rated voltage×2Note 4  
50mA max.  
125±3℃  
Duration  
100048/0 hrs  
Rated voltage×2  
50mA max.  
Applied voltage  
Charge/discharge current  
Recovery  
Applied voltage  
Charge/discharge current  
Recovery  
6 to 24hrStandard conditionNote 5  
24±2 hrsStandard conditionNote 5  
Note 1 The figures indicate typical specifications. Please refer to individual specifications in detail.  
Note 2 Thermal treatment : Initial value shall be measured after test sample is heat-treated at 1500/10for an hour and kept at room temperature for 24±2hours.  
Note 3 Voltage treatment : Initial value shall be measured after test sample is voltage-treated for an hour at both the temperature and voltage specified in the test conditions, and  
kept at room temperature for 24±2hours.  
Note 4 150% of rated voltage is applicable to some items. Please refer to their specifications for further information.  
Note 5 Standard condition: Temperature: 5 to 35, Relative humidity: 45 to 85 % RH, Air pressure: 86 to 106kPa  
When there are questions concerning measurement results, in order to provide correlation data, the test shall be conducted under the following condi-  
tion.  
Temperature: 20±2, Relative humidity: 60 to 70 % RH, Air pressure: 86 to 106kPa  
Unless otherwise specified, all the tests are conducted under the "standard condition".  
This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.  
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.  
mlcc_reli_e-01  
mlcc_reli-R4  
 复制成功!