HV582
Absolute Maximum Ratings*
Supply Voltage, V
DD
Supply Voltage, V
PP
Logic input levels
Ground current
High voltage supply current
Continuous total power dissipation
Operating temperature range
Storage temperature range
* All voltages are referenced to device ground.
Ordering Info
Device
HV582
* Contact Factory
-0.5V to 6V
V
DD
to 100V
-0.5V to V
DD
+0.5V
TBD A
TBD A
TBD mW
-40°C to +85°C
-65°C +150°C
Recommended
Operating V
PP
Max
90V
Package Options
Die
HV582X
Notes:
Power-up sequence should be the following:
1. Connect ground.
2. Apply V
DD
.
3. Set all inputs (Data, CLK, Enable, etc.) to a known state.
4. Apply V
PP
.
Power-down sequence should be the reverse of the above.
DC Electrical Characteristics
(Over operating supply voltages unless otherwise noted)
Symbol
I
DD
I
DDQ
I
PP
I
IH
I
IL
R
IN
V
OH
V
OL
V
OC
I
OH
Parameter
V
DD
supply current
Quiescent V
DD
supply current
High voltage supply current
High-level logic input current
Low-level logic input current
Pull-down resistance (DIR, POL, [not]OE,
OH, OL)
HV
OUT
High-level output
Data out
Min
Typ
Max
25
100
TBD
TBD
1.0
-1.0
Units
mA
µA
mA
µA
µA
Conditions
f
CLK
=30MHz, LE*=LOW
All V
IN
=0V or V
DD
V
PP
=90V, all outputs high
V
PP
=90V, all outputs low
V
IH
=V
DD
V
IL
=0V
V
PP-10
V
DD-1
10
1.0
V
V
V
V
PP
=90V, I
HVOUT
=-75mA
I
DOUT
=-4.0mA
VDD =5.0V, IHVOUT=75mA
I
DOUT
=-4.0mA
I
OH
=75mA
I
OL
=-75mA
V
PP
=100V
Low-level output
HV
OUT
clamp voltage
Output source current
HV
OUT
Data out
100
mA
2