HV513
Operating Supply Voltages
Symbol
Parameter
Min
4.5
Typ
Max
5.5
Units
V
Conditions
VDD
Logic supply voltage
5.0
VPP
High voltage supply
30
250
VDD
0.9
V
Note 1
VIH
High-level input voltage
Low-level input voltage
Operating free-air temperature
VDD-0.9
0
V
VIL
V
TA
-40
+85
° C
Notes:
1. Below minimum VPP the output may not switch.
2. Power-up sequence should be the following:
1. Connect ground.
2. Apply VDD
3. Set all inputs (Data, CLK, Enable, etc.) to a known state.
4. Apply VPP
.
.
Power-down sequence should be the reverse of the above.
Input and Output Equivalent Circuits
V
DD
V
DD
V
PP
*
20kΩ
Data Out
HV
OUT
Input
GND
GND
HV
GND
Logic Inputs
Logic Data Output
High Voltage Outputs
*
POL, BL, LE, and HI-Z
3