HV302 / HV312  
Design Information  
Programming Under and Over Voltage Shut Down  
Under Voltage/Over Voltage Operation  
The UV and OV pins are connected to comparators with nominal  
1.21V thresholds and 100mV of hysteresis (1.21V ± 50mV). They  
are used to detect under voltage and over voltage conditions at the  
input to the circuit. Whenever the OV pin rises above its high  
threshold (1.26V) or the UV pin falls below its low threshold  
(1.16V) the GATE voltage is immediately pulled low, the PWRGD  
pin changes to its inactive state and the external capacitor  
connected to the RAMP pin is discharged.  
Calculations can be based on either the desired input voltage  
operating limits or the input voltage shutdown limits. In the  
following equations the shutdown limits are assumed.  
From the calculated resistor values the OV and UV start up  
threshold voltages can be calculated as follows:  
The under voltage and over voltage shut down thresholds can be  
programmed by means of the three resistor divider formed by R1,  
R2 and R3. Since the input currents on the UV and OV pins are  
negligible the resistor values may be calculated as follows:  
R2 + R3  
UVON = VUVH = 1.26 = VEEUV(on)  
OVON = VOVL = 1.16 = VEEOV(on)  
×
R1+ R2 + R3  
R2 + R3  
UVOFF = VUVL = 1.16 = VEEUV(off)  
OVOFF = VOVH = 1.26 = VEEOV(off)  
×
×
R1+ R2 + R3  
R3  
R3  
×
R1 + R2 + R3  
R1+ R2 + R3  
Where VEEUV(on) and VEEOV(on) are Under & Over Voltage Start  
Up Threshold points.  
Where VEEUV(off) and VEEOV(off) are Under & Over Voltage Shut  
Down Threshold points.  
Then  
If we select a divider current of 100µA at a nominal operating input  
voltage of 50 Volts then  
R1+ R2 + R3  
R2 + R3  
VEEUV(on) = 1.26 ×  
50V  
100uA  
R1+ R2 + R3 =  
= 500k  
487k+ 6.81k+ 9.76kΩ  
VEEUV(on) = 1.26 ×  
= 38.29V  
= 59.85V  
From the second equation for an OV shut down threshold of 65V  
the value of R3 may be calculated.  
6.81k+ 9.76kΩ  
And  
65 ×R3  
OVOFF = 1.26 =  
500k  
R1+ R2 + R3  
VEEOV(on) = 1.16 ×  
VEEOV(on) = 1.16 ×  
R3  
1.26 × 500K  
R3 =  
= 9.69kΩ  
487k+ 6.81k+ 9.76kΩ  
9.76kΩ  
65  
The closest 1% value is 9.76kΩ  
Therefore, the circuit will start when the input supply voltage is in  
the range of 38.29V to 59.85V.  
From the first equation for a UV shut down threshold of 35V the  
value of R2 can be calculated.  
35 ×  
(
R2 + R3  
)
UVOFF = 1.16 =  
500K  
1.16 × 500k  
R2 =  
9.76k= 6.81kΩ  
35  
The closest 1% value is 6.81kΩ  
Then  
R1 = 500KR2 R3 = 483kΩ  
The closest 1% value is 487kΩ  
6
Rev. D  
04/17/02  
Supertex, Inc. 1235 Bordeaux Drive, Sunnyvale, CA 94089 TEL: (408) 744-0100 Fax: (408) 222-4895 www.supertex.com  